19
Version 0
RECEIVER
TRANSMITTER
RECEIVER
TRANSMITTER
TRANSMITTER
RECEIVER
RCM II
ROM II
RS422
To Alarm Panel
Tampers to Alarm Panel
Tampers to Alarm Panel
Tampers to Alarm Panel
Figure 19 – Free Running Example
5.2 Tethered Mode
In the Tethered mode the controller and laptop are connected to the MicroWave 330 receiver as shown in Figure
20. MicroWave 330 setup and detection parameters are configured using the Universal Installation Service Tool
II (UIST II) running on a laptop or desktop computer connected to the RS232 Configuration Port, Com 3. Alarm
reporting is configured at the controller and is communicated on the RS422 alarm polling network, Com 1 and
Com 2. If a CM II or GCM II controller is used, MicroWave 330 can be configured using the UIST II through
the controller.
Figure 20 – Tethered Mode
The Tethered mode requires a wire connection between the transmitter and receiver for synchronous operation.
The modulation signal from the receiver is provided on the tether to the transmitter and the transmitter tamper is
wired into the External Tamper Input on the receiver so it is included in the alarm polling network. The tether
also allow for changing the modulation frequency using the UIST II.
Содержание MicroWave 330