505-00060B
INSTALLATION & OPERATING
INSTRUCTIONS
For technical assistance, please call 1-800-780-4324 x 20311
Manufactured by Southwire Company, LLC, 4525 140th Avenue North, Suite 900, Clearwater, Florida 33762
© 2017 Southwire Company, LLC. All rights reserved. * Trademark of Southwire Company, LLC. Registered in the United States.
MODEL 67060
SAVE THESE INSTRUCTIONS
INSTALLATION INSTRUCTIONS
MODEL 67060
PLEASE READ THESE INSTRUCTIONS CAREFULLY.
In the event you have any questions concerning use or care of this product, please contact the sales department at Southwire Company, LLC.
Installation Procedure
1. Plug the Surge Guard Model 67060 into an approved 120V/30A marine power receptacle.
2. Press and release the reset button. Verify that the Green light is visible.* This indicates power is available to the watercraft.
3. Press the test button. Verify that the Green light is not visible.
4. Press and release the reset button. Verify that the Green light is visible.
5. Power is available. Operate equipment in your watercraft normally.
* If the unit is in the reset condition when plugged into the power receptacle, then the green light will be immediately visible.
Warning
1. If the unit with contacts closed fails to trip when test button is pressed (Green light fails to extinguish), the device is not operating
properly and should be returned to the point of purchase for replacement (see warranty information).
2. If the product tests properly without a load applied, but trips each time the watercraft load is applied, a current leakage exists and
should be repaired or replaced as soon as possible (see warranty information). DO NOT BYPASS THE SURGE GUARD UNIT IF
THIS CONDITION OCCURS. A REAL SHOCK HAZARD MAY EXIST.
• Read all instruction before using the appliance.
• To reduce risk of injury, close supervision is necessary when an appliance is used near children.
• Do not connect any electrical cord longer than 250 feet to the Surge Guard unit to avoid the possibility of nuisance tripping.
• This device is to be used on electrical distribution systems 120V/30A 60Hz only.
• Ground fault circuit interrupters do not protect against electrical shock resulting from contact with both line and
neutral wires of the electrical circuit.
• The Surge Guard Model 67040 is designed as a protective device, do not use as an “on and off” switch.
WARNING
– The Surge Guard Model 67060 will provide protection even if there
is a break in the ground wire in the supply power circuit or the internal circuit in
the water craft. When using electric appliances, basic precautions should always
be followed, including: