background image

TECHNICAL SPECIFICATIONS

1.  Plug the RV power cord into an approved RV receptacle.
2.  Verify the delay indicator is flashing, and the line lights are green.
3.  Once caution light stops flashing (this takes 128 seconds), verify RV 

power is on.

NOTE: USING SURGE Guard* VOLTAGE REGULATOR 

If using Surge Guard* Voltage Regulator (10175 or 10176) the voltage 

regulator should be positioned between the power pedestal (shore power) 

and the Surge Guard* product.

WARNING:  

It is extremely important that the terminal covers 

(Model 35530 only) are in place prior to applying power to the RV.  

Failure to comply with these instructions may result in a shock 

hazard.

OPERATING INSTRUCTIONS

TROUBLESHOOTING

FEATURES

MODEL 35530

MODEL 35550

Operating Current

30 Amps

50 Amps

Operating Voltage

120 Volts

120/240 Volts

Maximum Watts

3600 Watts

12000 Watts

3 Mode Surge Protection

Yes, L-N, L-G,N-G

Yes, L-N, L-N, L-G, 

N-G, L-L

Energy Dissipation

2450 Joules

3850 Joules

Maximum Spike Current

6500A per MOV

6500A per MOV

Over/Under Voltage Protection

Yes

Yes

Voltage Range

132/102V

132/102V

Trip Time

8-10 seconds

8-10 seconds

High Neutral Current Trip

N/A

130%

Time Delay for A/C

128 seconds

128 seconds

Reverse Polarity Protection

Yes

Yes

Voltage On Ground Check

Yes

Yes

Power Indicator

Yes (1 line light)

Yes (2 line lights)

Warranty 

1 year

1 year

Corrosion Resistant

Yes

Yes

Easy Installation

Yes

Yes

Industrial Contactor

Yes

Yes

SYMPTOM

CAUSE

SOLUTION

Caution light is 

flashing

1.  Reverse polarity or 

voltage on ground 

condition is present at 

the power source.

2.  Surge Guard mis-wired 

on the line side.

3.  Open ground circuit on 

the line side

1.  Move RV to new 

electrical source.

2.  Match colors 

on terminals 

with colors on 

conductors.

3.  Move RV to new 

electrical source.

L1 and/or L2 is 

red or off, and 

caution light is 

flashing

1.  Only partial power at 

50 Amp source.

2.  No power at source

1.  Move to a new 

source

2.  Use inverter or 

generator power

SURGE light 

is on

1.  Built-in surge 

protection has been 

sacrificed to protect 

your equiptment and is 

no longer functioning.   

2.  Other features will 

still function, but it 

is recommended to 

replace unit.

INDICATOR LIGHT CHART

MODEL 35530

CONDITION 

DESCRIPTION

INDICATOR LIGHT STATUS

RV POWER

LINE 1

DELAY/CAUTION

Normal Conditions

green

off

on

Startup Condition

on

flashing

off

Reverse Polarity

on

flashing

off

Open Ground

on

flashing

off

Voltage on Ground

on

flashing

off

Over or Under Voltage

red

flashing

off

No Power at L1

off

off

off

MODEL 35550

CONDITION 

DESCRIPTION

INDICATOR LIGHT STATUS

RV 

POWER

LINE 1

LINE 2

DELAY/CAUTION

Normal Conditions

green

green

off

on

Startup Condition

on

on

flashing

off

Reverse Polarity

on

on

flashing

off

Open Ground

on

on

flashing

off

Voltage on Ground

on

on

flashing

off

Over or Under Voltage

red

red

flashing

off

Power to Line 1 Only

on

red

flashing

off

Power to Line 2 Only

off

off

off

off

No Power at Input

off

off

off

off

BLACK

GREEN

WHITE

BLACK
WHITE

GREEN

BLACK

GREEN

WHITE

LINE

(INPUT)

LOAD

(OUTPUT)

IMPORTANT NOTE: MAX TORQUE PER CONNECTION = 7 IN-LBS.

DO NOT EXCEED.

120V- 30A  

MODEL# 35530

FIGURE 5A

505-00115C