Southwire 22070T Скачать руководство пользователя страница 3

3

General Specifications cont.

Safety

For indoor use and in accordance with UL-61010-1 2nd edition. It has been

evaluated and complies with overvoltage CAT III. Pollution degrees 2.

International Safety Symbols

Potential danger. Indicates the user must refer to the

manual for important safety information.
Indicates hazardous voltages may be present

Equipment is protected by double or reinforced insulation

Indicates the terminal(s) so marked must not be connected to a circuit where

the voltage with respect to earth ground exceeds the maximum safety rating

of the meter .
Indicates the terminal(s) so marked may be

subjected to hazardous voltages.

MAX

600V

The measurement category (CAT) rating and voltage rating is determined by a combination of the meter,

test probes and any accessories connected to the meter and test probes.

The combination rating is the LOWEST of any individual component.

Brief Description

Typical Applications

Category

Rating

Single phase receptacles

and connected loads 

Three phase circuits and

single phase lighting

circuits in commercial

buildings 

- Household appliances, power tools

- Outlets more than 30ft (10m) from a CAT III source

- Outlets more than 60ft (20m) from a CAT IV source
- Equipment in fixed installations such as 3-phase

   motors, switchgear and distribution panels 

- Lighting circuits in commercial buildings

- Feeder lines in industrial plants

- Any device or branch circuit that is close to a CAT III source

CAT II

CAT III

Safety Category Ratings 

WARNING: 

                                   Operation is limited to CAT II applications when the insulated tips are 

removed

from one or both test probes. Refer to Input Limits section of this manual for maximum voltage ratings.

CAT III 1000V

CAT IV 600V  

CAT II

1000V

Insulated Tip On

Insulated Tip Removed

4

Maintenance

This Clamp Meter is designed to provide years of dependable service,

if the following care instructions are performed:
1. KEEP THE METER DRY. If it gets wet, wipe it off.
2. USE AND STORE THE METER IN NORMAL TEMPERATURES. Temperature

    extremes can shorten the life of the electronic parts and distort or melt

    plastic parts.
3. HANDLE THE METER GENTLY AND CAREFULLY. Dropping it can damage the

    electronic parts or the case.
4. KEEP THE METER CLEAN. Wipe the case occasionally with a damp cloth.

    DO NOT use chemicals, cleaning solvents, or detergents.
5. USE ONLY FRESH BATTERIES OF THE RECOMMENDED SIZE AND TYPE.

    Remove old or weak batteries so they do not leak and damage the unit.
6. IF THE METER IS TO BE STORED FOR A LONG PERIOD OF TIME, the batteries

    should be removed to prevent damage to the unit.

Содержание 22070T

Страница 1: ...verdadera 12 14 Rev 1 22070T manual Contents Made in China Product distributed by Southwire Company LLC One Southwire Drive Carrollton GA 30119 2014 Southwire Company LLC All rights reserved southwire...

Страница 2: ...k hazard Do not use the meter in wet or damp environments or during electrical storms Do not use the meter near explosive vapors dust or gasses Do not use the meter if it operates incorrectly Protecti...

Страница 3: ...an 60ft 20m from a CAT IV source Equipment in fixed installations such as 3 phase motors switchgear and distribution panels Lighting circuits in commercial buildings Feeder lines in industrial plants...

Страница 4: ...7 RANGE select button 8 MODE select button 9 Relative button 10 MAX MIN button 11 LCD display 12 COM input jack 13 V CAP Temp Hz input jack 14 Non contact voltage detector AUTO POWER OFF MODE REL MAX...

Страница 5: ...ety precautions when working on live conductors WARNINGS 8 1 Set the rotary function switch to the VAC DC Hz position 2 Insert the black test lead into the negative COM input jack and the red test lea...

Страница 6: ...est lead probes to the device or wire being tested 5 A tone will sound if the resistance is approximately 30 ohms or less 10 Capacitance Measurements Operation cont 1 Set the rotary function switch to...

Страница 7: ...ts Operation cont 1 Set the rotary function switch to the Temp 0 F 0 C position 2 Push the to select readings in F or C 3 Connect the Temperature Probe to the Banana Plug Adapter Insert the adapter in...

Страница 8: ...ny LLC warrants this product to be free from defects in material and workmanship for two years from the date of purchase This warranty does not cover fuses disposable batteries or damage arising from...