Southwire 22070T Скачать руководство пользователя страница 1

AUTO

POWER

OFF

MODE

REL

MAX

MIN

RANGE

Hz%

Non-Contact

Voltage Detector

600V

CAT 

III

MAX MIN HOLD REL

0

10

20

30

40

50

60

Operating Instructions

22070T True RMS AC/DC CLAMP METER

Instrucciones de uso

Pinza amperimétrica de CA/CC de RMS verdadera  

12/14  Rev. 1
22070T manual

Contents Made in China
Product distributed by Southwire Company, LLC

One Southwire Drive, Carrollton, GA 30119
©2014 Southwire Company, LLC.  All rights reserved.

southwiretools.com

1-855-SW-T00LS

Toll Free Technical Help

Línea de Ayuda Técnica Gratuita

Scan for warranty information

and to access our mobile site.

Escanea para información de garan

tía

y acceso a nuestro sitio móvil. 

TESTING EQUIPMENT

E361819

Содержание 22070T

Страница 1: ...verdadera 12 14 Rev 1 22070T manual Contents Made in China Product distributed by Southwire Company LLC One Southwire Drive Carrollton GA 30119 2014 Southwire Company LLC All rights reserved southwire...

Страница 2: ...k hazard Do not use the meter in wet or damp environments or during electrical storms Do not use the meter near explosive vapors dust or gasses Do not use the meter if it operates incorrectly Protecti...

Страница 3: ...an 60ft 20m from a CAT IV source Equipment in fixed installations such as 3 phase motors switchgear and distribution panels Lighting circuits in commercial buildings Feeder lines in industrial plants...

Страница 4: ...7 RANGE select button 8 MODE select button 9 Relative button 10 MAX MIN button 11 LCD display 12 COM input jack 13 V CAP Temp Hz input jack 14 Non contact voltage detector AUTO POWER OFF MODE REL MAX...

Страница 5: ...ety precautions when working on live conductors WARNINGS 8 1 Set the rotary function switch to the VAC DC Hz position 2 Insert the black test lead into the negative COM input jack and the red test lea...

Страница 6: ...est lead probes to the device or wire being tested 5 A tone will sound if the resistance is approximately 30 ohms or less 10 Capacitance Measurements Operation cont 1 Set the rotary function switch to...

Страница 7: ...ts Operation cont 1 Set the rotary function switch to the Temp 0 F 0 C position 2 Push the to select readings in F or C 3 Connect the Temperature Probe to the Banana Plug Adapter Insert the adapter in...

Страница 8: ...ny LLC warrants this product to be free from defects in material and workmanship for two years from the date of purchase This warranty does not cover fuses disposable batteries or damage arising from...