Operation

MODE BUTTON

The MODE button is used to select AC or DC voltage, Hz or % Duty Cycle, Ohms, 

Diode Test, Continuity or Capacitance, and °F and °C. 

MAX/MIN Button

1. Momentarily press the 

MAX/MIN

 button to activate the MAX/MIN mode. “MAX” 

    will appear on the LCD display and the meter will display and hold the highest 
    reading. The meter will update the reading when a higher “max” occurs.
2. Momentarily press the 

MAX/MIN

 button again to view the lowest reading. 

    “MIN” will appear on the LCD display and the meter will display and hold the 
    lowest reading. The meter will update the reading when a lower “min” occurs. 
3. Press and hold the 

MAX/MIN

 button to end MAX/MIN and return to normal 

    operation. 

  NOTE:

 The meter does not Autorange when the MAX/MIN mode is active. 

  The display will read OL if the range is exceeded. MAX/MIN does not work on 

  Frequency, Duty Cycle, Diode Test, Continuity and Capacitance.

FLASHLIGHT Button

Press the       button to turn the flashlight on and off. 

    

MAX

MIN

n  m VA F M k

AUTO  HOLD   MAX  MIN   REL   LOZ

0

10

20

30

40

8

1. Set the rotary function switch 

    to the          position.
2. Press the MODE button to select 

    AC or DC voltage. The AC “

~

” or 

    DC “     ” symbol will appear on 

    the LCD display.

3. Insert the black test lead into 

    the 

COM

 input jack and the red 

    test lead into the 

V

 input jack. 

4. Touch the test lead probes to the circuit under test. 

    If measuring DC voltage, touch the red test lead to the 

    positive side of the circuit and the black test lead to the 

    negative side of the circuit.  

5. Read the voltage on the LCD display. 

AC/DC Voltage Measurements 

V

-

+

   Observe all safety precautions

when working on live voltages.

WARNING:  

Operation cont.

HOLD/Backlight button 

To freeze the reading on the display, momentarily press the 

HOLD

     button. “HOLD” 

will appear on the LCD display while the reading is being held. Momentarily press 

the 

HOLD

     button again to return to normal operation.

The backlight illuminates the LCD display when the ambient light is too low to view 

the displayed readings. To turn on, press the 

HOLD

     button until the backlight turns 

on. To turn off, press the 

HOLD

     button until the backlight turns off. 

MAX

MIN

n  m VA F M k

AUTO  HOLD   MAX  MIN   REL   LOZ

0

10

20

30

40

Содержание 032886963261

Страница 1: ...1010 1 S CURIT NOMIN A L E SAFETY RATED TESTING EQUIPMENT QUIPEMENT DE TEST IMPERM ABLE 6 16 Rev 0 13050S manual Contents Made in China Fabriqu en Chine Product distributed by Produit distribu par Sou...

Страница 2: ...tery warning is on Replace batteries immediately When replacing the battery or fuses be sure to secure the battery compartment door firmly to maintain the waterproof and dust proof integrity of the me...

Страница 3: ...EFULLY Dropping it can damage the electronic parts or the case 4 KEEP THE METER CLEAN Wipe the case occasionally with a damp cloth DO NOT use chemicals cleaning solvents or detergents 5 USE ONLY FRESH...

Страница 4: ...hlight 1 2 4 5 7 8 9 10 6 3 6 Symbols Used on LCD Display V A Hz F F C n m k M OL AUTO HOLD MAX MIN Volts Amperes Alternating current Direct current Minus sign Hertz frequency Percent duty cycle Ohms...

Страница 5: ...Mk AUTO HOLD MAX MIN REL LOZ 0 10 20 30 40 8 1 Set the rotary function switch to the position 2 Press the MODE button to select AC or DC voltage The AC or DC symbol will appear on the LCD display 3 In...

Страница 6: ...urrent on the LCD display AC Current Measurements Observe all safety precautions when working on live circuits Do not measure current on circuits that exceed 600V Measurements in the 10A range should...

Страница 7: ...30 40 MAX MIN n m VA FMk AUTO HOLD MAX MIN REL LOZ 0 10 20 30 40 MAX MIN n m VA FMk AUTO HOLD MAX MIN REL LOZ 0 10 20 30 40 11 Operation cont 1 Set the rotary function switch to the position 2 Press t...

Страница 8: ...urely fastened to the meter WARNING To avoid electric shock remove the test leads from the meter before removing the battery fuse cover WARNINGS MAX MIN n m VA FMk AUTO HOLD MAX MIN REL LOZ 0 10 20 30...

Страница 9: ...ity of the meter Loose or overtightened screws or an improperly seated o ring may compromise the meter s water and dust ingress protection WARNING 16 Specifications 4 000V 40 00V 400 0V 600V Input Pro...

Страница 10: ...Range Resolution Accuracy of reading digits 0 1 to 99 9 Input Protection 250V AC RMS or 250V DC Pulse Width 100 s 100ms Frequency Range 5Hz to 150kHz Sensitivity 8V RMS 0 1 1 2 2 digits Duty Cycle Fu...

Страница 11: ...RANTY This warranty is void if this product is used for rental purposes No product reseller is authorized to extend any other warranty on Southwire s behalf relating to this product and no such resell...

Страница 12: ...tre s il ne fonctionne pas normalement Sa protection peut tre compromise N utilisez pas le multim tre lorsque l avertissement de pile faible est allum Remplacez les piles imm diatement Apr s le rempla...

Страница 13: ...la t l vision ce qu on peut d terminer en teignant et rallumant l quipement l utilisateur est invit essayer de corriger l interf rence par une ou plusieurs des mesures suivantes R orientez ou d place...

Страница 14: ...oche 1 2 4 5 7 8 9 10 6 3 6 Symboles utilis s sur l cran LCD V A Hz F F C n m k M OL AUTO HOLD MAX MIN Volts Amp res Courant alternatif Courant continu Signe moins Hertz fr quence Pour cent rapport cy...

Страница 15: ...port cyclique de test de diode de continuit et de capacit Bouton de la lampe de poche Appuyez sur le bouton pour allumer ou teindre la lampe de poche MAX MIN n m VA FMk AUTO HOLD MAX MIN REL LOZ 0 10...

Страница 16: ...rapport cyclique en Le symbole Hz ou appara t sur l cran LCD 3 Ins rez la sonde noire dans le connecteur d entr e COM et ins rez la sonde rouge dans le connecteur d entr e V 4 Placez les pointes des s...

Страница 17: ...ecte Tension inverse MAX MIN n m VA FMk AUTO HOLD MAX MIN REL LOZ 0 10 20 30 40 MAX MIN n m VA FMk AUTO HOLD MAX MIN REL LOZ 0 10 20 30 40 Sonde rouge Sonde rouge Sonde noire Sonde noire MAX MIN n m V...

Страница 18: ...piles est bien fix pour maintenir l tanch it la poussi re et l eau Cette tanch it peut tre compromise par des vis desserr es ou trop serr es ou par un joint torique mal plac AVERTISSEMENT MAX MIN n m...

Страница 19: ...sion CC 15 Fonctionnement suite Remplacement du fusible 1 Relevez le support inclin 2 Retirez les vis Phillips sur le couvercle du compartiment des piles et du fusible 3 Enlevez le couvercle du compar...

Страница 20: ...rotection d entr e 250 VCA RMS ou 250 VCC Sensibilit 0 5 V RMS 1 MHz 3 V RMS 1 MHz 0 001 Hz 0 01 Hz 0 1 Hz 1 Hz 10 Hz 100 Hz 1k Hz 1 5 5 chiffres 1 2 3 chiffress 1 5 4 chiffres Fr quence Fonction Plag...

Страница 21: ...ntie ne s applique pas si le produit est acquis des fins de location Aucun revendeur de ce produit n est autoris tendre la port e de cette garantie au nom de Southwire et s il le fait Southwire ne ser...

Страница 22: ...si la advertencia de Bater a Baja est encendida Cambie las bater as inmediatamente Al cambiar la bater a o los fusibles aseg rese de fijar la tapa del compar timiento de la bater a con firmeza para m...

Страница 23: ...sionar o fundir las piezas de pl stico 3 MANEJE EL PROBADOR CON DELICADEZA Y CUIDADO El dejarlo caer puede da ar las piezas electr nicas o la caja 4 MANTENGA LIMPIO EL PROBADOR Ocasionalmente limpie l...

Страница 24: ...rna 1 2 4 5 7 8 9 10 6 3 6 S mbolos Utilizados en la Pantalla LCD V A Hz F F C n m k M OL AUTO HOLD MAX MIN Voltios Amperios Corriente alterna Corriente continua Signo de menos Hertz frecuencia Por ci...

Страница 25: ...Z 0 10 20 30 40 8 1 Coloque el interruptor de funci n rotativa en la posici n 2 Pulse el bot n de MODE para seleccionar el voltaje AC o DC El s mbolo de AC o DC aparecer en la pantalla LCD 3 Inserte e...

Страница 26: ...nerg a al circuito 6 Lea la corriente en la pantalla LCD Mediciones de Corriente AC Siga todas las precauciones de seguridad cuando trabaje en circuitos vivos No mida corriente en circuitos que exceda...

Страница 27: ...Prueba de retroceso MAX MIN n m VA FMk AUTO HOLD MAX MIN REL LOZ 0 10 20 30 40 MAX MIN n m VA FMk AUTO HOLD MAX MIN REL LOZ 0 10 20 30 40 MAX MIN n m VA FMk AUTO HOLD MAX MIN REL LOZ 0 10 20 30 40 MA...

Страница 28: ...r hasta que la cubierta de la bater a fusible est bien conectado al probador ADVERTENCIA Para evitar descargas el ctricas retire los cables de prueba del medidor antes de retirar la cubierta de la bat...

Страница 29: ...te el soporte de inclinaci n 2 Afloje los tornillos de estrella en la cubierta de la bater a fusible 3 Retire la cubierta de la bater a fusible 4 Retire con cuidado el fusible e instale un fusible nue...

Страница 30: ...999 9kHz 9 999MHz Protecci n de Entrada 250V AC RMS o 250V DC Sensibilidad 0 5V RMS 1MHz 3V RMS 1MHz 0 001Hz 0 01Hz 0 1Hz 1Hz 10Hz 100Hz 1kHz 1 5 5 d gitos 1 2 3 d gitos 1 5 4 d gitos Frecuencia Func...

Страница 31: ...UIER INCUMPLIMIENTO DE ESTA GARANT A Esta garant a no ser v lida si el producto se utiliza para prop sitos de alquiler Ning n vendedor de productos est autorizado a extender la garant a a nombre de So...

Отзывы: