background image

Electronic Key Controller
User Instructions

J-EA-B90-M_revD

visit

www.southco.com

for latest version of this document

Page 2 of 2

Enrolling Programming Key (initial setup)

The controller allows for one programming key to be enrolled. By default,
the controller is shipped with no programming or user keys enrolled. The
first key to be enrolled will become the programming key. To enroll the
programming key:

1.

Apply power. The reader will flash red/green.

2.

Contact the key to the reader. The reader will turn solid amber if
enrollment is successful.

Once the programming key has been enrolled, the controller will enter its
programming mode, indicated by the reader turning amber.

Enrolling User Keys

1.

Contact the programming key to the reader (skip this step if this
is during initial setup).
a.

The reader will turn solid amber to indicate programming
mode has been entered.

b.

If the key made poor contact with the reader, the reader will
flash red three times to indicate a bad read.

2.

Contact the user key to the reader.
a.

The reader will flash green eight times if enrollment is
successful.

b.

If the key made poor contact with the reader, the reader will
flash red once to indicate a bad read.

3.

To enroll additional user keys, wait for the reader to turn solid
amber, and then repeat Step #2.

Note:

The controller supports a maximum of 15 user keys. The

reader will flash red/green if more than 15 keys are attempted to
be enrolled.

4.

Contact the programming key to the reader when done. The
reader will turn “off” indicating that enrollment is complete. The
controller will exit programming mode.

Deleting User Keys

1.

Contact the programming key to the reader.
a.

The reader will turn solid amber to indicate programming
mode has been entered.

b.

If the key made poor contact with the reader, the reader will
flash red three times to indicate a bad read.

2.

Contact the user key to the reader.
a.

The reader will flash red eight times to indicate that removal
was successful.

b.

If the key made poor contact with the reader, the reader will
flash red once to indicate a bad read.

3.

To delete additional user keys, wait for the reader to turn solid
amber, and then repeat Step #2.

4.

Contact the programming key to the reader when done. The
reader will turn “off” indicating that removal is complete. The
controller will exit programming mode.

Changing Access Time

The default access time is 5 seconds. The access time can be increased
in 5 second increments to a maximum of 30 seconds by pressing the S1
switch on the PCA inside the controller box while the controller is in
programming mode.

1.

Contact the programming key to the reader.
a.

The reader will turn solid amber to indicate programming
mode has been entered.

b.

If the key made poor contact with the reader, the reader will
flash red three times to indicate a bad read.

2.

Press the S1 switch on the PCB inside the controller box to add
5 seconds to the access time. The reader will blink once.

3.

Repeat Step #2 to increase access time in 5 second increments.

Note:

The maximum access time is 30 seconds. The reader will

alternate flashing red/green and the access time will be set to 5
seconds if the 30 second maximum is exceeded.

4.

Contact the programming key to the reader when done. The
reader will turn “off” indicating that the access time has been set.
The controller will exit programming mode.

S1 switch

S1 switch

Resetting the Controller

Resetting the controller will erase the programming and all user key
permissions. Access time will be reset to 5 seconds. To reset the
controller:

1.

Remove power.

2.

Press and hold the S1 switch on the PCB inside the controller
box while re-applying power. The reader will be amber at power-
on while the S1 switch is pressed in.

3.

Release the S1 switch. The reader will alternate red/green.

Follow the instructions from “

Enrolling Programming Key (initial setup)

section to enroll the programming key.

Normal Use

For normal use, contact a user key to the reader.

If an enrolled user key makes proper contact with the reader, the reader
will turn solid green and access will be granted for the programmed access
time.

If an un-enrolled key makes contact with the reader, the reader will
alternate flashing red/green for approximately 3 seconds.

If a key does not make proper contact with the reader, the reader will flash
red three times to indicate a bad read.

CAUTION:

A controller that has been programmed is non-returnable.

Please use caution in programming functions so as not to render the
controller unusable.

For technical support of this product contact:

[email protected]

or visit:

www.southco.com

.

Отзывы: