background image

Electronic Key Controller
User Instructions

J-EA-B90-M_revD

visit

www.southco.com

for latest version of this document

Page 1 of 2

Specifications

Supply Voltage:

12VDC ± 10%

Quiescent Current:

100µA (max)

Operating Current:

35mA (max)

Command Output Signal Rating:

2A @ 12V (max)

Number of Users:

15 (max)

Access Time:

programmable 5- 30 seconds
(default 5 seconds)

CAUTION

: The electronic key controller PCA is an ESD-sensitive

device. Observe ESD best practices when accessing the PCA to avoid
damage to the PCA.

Electronic Key Controller

power supply input

controller output to EML

reader input

power supply input

controller output to EML

reader input

NOTE:

This controller is designed to work with Southco electronic key

reader part number (EA-B30-xxx).

Assembly and Installation

The electronic key controller is part of a system that requires connection to
a power supply, electronic key reader, and electromechanical latch (EML)
to function properly.

Power Supply

The controller requires a 12VDC power supply. Be sure to observe correct
polarity.

GND (pin 2)

VCC (pin 1)

GND (pin 2)

VCC (pin 1)

pin #

description

1

VCC (power supply input)

2

GND (ground)

Controller Output to EML

The controller output connector provides a power supply and command
output for an electromechanical latch. Please note that these will be the
same voltage level as the controller’s power supply voltage (12VDC).

command output

(pin 3)

VCC

(pin 2)

GND

(pin 1)

command output

(pin 3)

VCC

(pin 2)

GND

(pin 1)

pin #

description

1

GND (ground)

2

VCC (power supply)

3

command output

4

no-connect

5

no-connect

6

no-connect

Electronic Key Reader Input

The electronic key reader reads the ID code from the electronic key and
sends it to the controller. The ID code is unique for each electronic key.

green LED control

(pin 1)

data signal

(pin 5)

red LED control

(pin 3)

GND

(pin 6)

GND

(pin 2)

green LED control

(pin 1)

data signal

(pin 5)

red LED control

(pin 3)

GND

(pin 6)

GND

(pin 2)

pin #

description

1

green LED control

2

GND (ground)

3

red LED control

4

no-connect

5

data signal

6

GND (ground)

Types of Keys

There are two types of electronic keys for this controller:

1.

Programming Key. There is one programming key. This key is
used to add and delete users. The programming key cannot be
used as a user key.

2.

User Key. The controller allows for a maximum of 15 user keys
to be enrolled. When an enrolled user key makes proper contact
with the reader, the reader will turn green and access will be
granted for the programmed access time. Note that to make
proper contact, the key must be centered and flat against the
reader.

Reader LED Color Codes

Programming Mode

color

description

solid amber

waiting for input

eight green flashes

user key enrolled

eight red flashes

user key deleted

alternating red/green

user key capacity full

one red flash

bad key read

User Mode

color

description

solid green

access granted (enrolled key)

alternating red/green

access denied (un-enrolled key)

three red flashes

bad key read

Отзывы: