Figure 11
Steamer Not Heating Up, “Power” Light Is Not Lit
DISCONNECT POWER AT CIRCUIT BREAKER
Steamer not heating up, “Power” light not lit.
Test operation of power switch. Replace if necessary. If power
switch is OK, replace “Power” light and follow procedure.
Replace Power Cord
Check continuity across
Power Switch
Is continuity
present?
No
Yes
DISCONNECT POWER AT CIRCUIT BREAKER
Remove right side panel for access.
Reconnect power at circuit breaker.
Turn lever to ON position and close door (to actuate door switch).
Check continuity between cord and TB5 and TB6
No
Yes
Check voltage between TB5 and TB6
Replace Power Switch
Replace Power Light
No
Yes
Is continuity present?
Is measured
voltage 120, 208, 220, or 240
volts?