T
ROUBLESHOOTING
Problem
Look for -
Griddle will not heat up
– Main gas supply to griddle is “OFF”
– Pilot(s) not lit
– Defective thermostat(s)
– Clogged orifice or burner ports
Burners produce excessive carbon deposits
– Incorrect gas type or orifice size
– Incorrect supply pressure
– Incorrect burner air mixer adjustment
– Burner orifice out of alignment with burner
– Incorrect orifices
Pilot produces excessive carbon deposits
– Pilot gas not adjusted properly
– Incorrect pilot orifice
Pilot will not stay lit
– Pilot not adjusted properly
– Clogged or dirty orifice
– Draft condition
– Improper ventilation system
– Air in gas line
– Valve end of thermocouple corroded or loose
– Pilot shield needs to be moved closer to pilot
– Improper gas pressure
– Incorrect gas supply size (not enough volume)
– Defective thermocouple
Electronic ignition module (on models so equipped) will not
generate a spark
– Dead battery in ignition module
– Defective spark module