Description

Water Capacity

NOD14

Cook Station

12 Gals. (45.5 Ltr.)

NODR14

Rinse Station

10 Gals. (37.9 Ltr.)

Tank Capacity

2.2.  FILLING THE APPLIANCE 
 

2.2.1.  FILLING THE COOKER TANK 
It is recommended that the cooker tank is filled with hot water.  This will greatly decrease the time 
it takes for the appliance to reach operating temperature. Refer to the following procedure to fill 
the cook tank prior to operation. 

 

 

1.  Ensure that the drain valve is closed, See Figure 3. 

 

2.  Fill the tank with water until the water reaches the water level line(s). 

 

2.2.2.  FILLING THE RINSE TANK 
Once pasta is cooked to the desired doneness it will continue to cook after being removed from 
the cook tank until its internal temperature is lowered. Submerging the pasta into cold water or 
rinsing it with cold water will lower the pasta’s internal temperature and stop the cooking process.  
Rinsing or submerging will also prevent sticking and remove dissolved starch.  If the appliance is 
equipped with a rinse tank, it may be filled with cold (or ice) water for submerging the pasta after 
it leaves the cook tank.  Refer to the following procedure to fill the cook tank prior to operation. 

 

1. 

Ensure that the drain valve is closed, Drain handle has the same closed position as the cook 

station.

 

2. Fill the tank with cold water (and ice if desired) until the water reaches the water level line(s). 

If the rinse tank does not have level lines, fill the tank so that the water is 4 inches 
(10.16cm) below the overflow. The tank can be filled up beyond the desired level but water 
may be lost through the overflow once pasta is placed into the tank. 

 

2.3. APPLIANCE 

START 

UP 

Refer to the following procedure to start the appliance prior to operation. 

 

1.  Ensure that the drain valve is closed, See Figure 3. 
2.  Fill the cook tank with water.  (See section 2.2.1 “Filling the Appliance”) 
3.  Light the appliance.  (See section 1.9.2 “Lighting Instructions”) 
4.  The appliance is now on and heating the water in the cook tank. 
5.  Press the ON/OFF (I/O) Button once to Toggle to between Boil and Simmer Mode, see 

Sections 2.4.1 and 2.4.2. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

*The specified 

button may appear 

slightly different than shown.  Refer to the operator’s manual for your appliance’s specific 
control type to determine the exact appearance of each button and display.

 

Содержание NOD14

Страница 1: ...nual NOD14 Floor Model Gas Pasta Cooker NODR14 Floor Model Rinse Station Southbend A Middleby Corporation Company 1100 Old Honeycutt Road Fuquay Varina NC 27526 919 762 1000 phone 919 552 9798 fax D E...

Страница 2: ...r safety Do not allow children to operate or play on or around the appliance WARNING If the appliance is equipped with a power cord and it is damaged it must be replaced by a Pitco Authorized Service...

Страница 3: ...G INSTRUCTIONS 8 1 8 3 SELF CLEANING BURNER SYSTEM 9 1 8 4 PILOT FLAME ADJUSTMENT 9 1 8 5 MAIN BURNER SYSTEM ADJUSTMENT 10 1 9 INITIAL CLEANING 11 2 OPERATION 12 2 1 OPERATIONAL FEATURES 12 2 2 FILLIN...

Страница 4: ...18 3 3 2 CONTROLLER 18 3 3 3 CONTROL BOX ELECTRICAL COMPONENTS 18 3 3 4 TANK 19 3 3 5 DRAIN SYSTEM 19 3 3 6 GAS COMBUSTION SYSTEM 19 3 4 VENTILATION HOOD 19 4 TROUBLESHOOTING 20 4 1 POWER FAILURE 20 4...

Страница 5: ...per is only responsible for 15 days after delivery Check the packing list enclosed with your appliance to ensure that you have received all the parts to the appliance If you are missing any parts cont...

Страница 6: ...minimum clearance requirements specified in this manual CAUTION To prevent equipment damage and or personal injury do not tilt the appliance onto any two of its casters or legs or pull the appliance b...

Страница 7: ...rs 1 Remove all loose accessories and carefully place the appliance on its back to avoid damage to the cabinet and splash back Protect the outside of the appliance with cardboard or a drop cloth when...

Страница 8: ...liance to reach operating temperature Prior to installation a water treatment specialist should inspect the water supply Water hardness should contain no more then 2 0 grains gallon The pH level shoul...

Страница 9: ...ously at full demand The pressure at the gas valve must not exceed 1 2 PSI Each appliance is equipped to operate on one certain fuel type The type of fuel with which the appliance is intended to opera...

Страница 10: ...This will prevent the appliance from being operated without the ventilator on If your appliance requires an electrical connection the power requirements are listed below 1 6 VENTILATION AND FIRE SAFET...

Страница 11: ...the flue opening WARNING NEVER connect the ventilation blower or hood directly to the flue of this appliance The resulting increased flow of air through the combustion system will cause improper opera...

Страница 12: ...til the water reaches the water level line approx 12 Gals 1 8 2 LIGHTING INSTRUCTIONS Refer to the following instructions to light the appliance 1 Open the shut off valve 2 for each cooking appliance...

Страница 13: ...roampmeter between the Pilot flame sensor terminal 11 and the ignition wire Not Shown Observe proper polarity if the meter needle goes below 0 reverse the leads The current reading must be 1 0 A or gr...

Страница 14: ...supply line installation which will cause poor performance of all appliances during peak usage The main gas supply pressure should only be checked by an authorized professional 3 The pressure reading...

Страница 15: ...s on the food contact surfaces 1 9 INITIAL CLEANING When your appliance is shipped many of its parts may be covered with a thin coat of oil for protection Before the appliance is used for cooking it m...

Страница 16: ...ng if the drain valve is opened 5 Drain Outlet Water exits the cook tank through the drain outlet when draining or overflowing 6 Overflow Line When the cook tank water level reaches the overflow water...

Страница 17: ...NOD14 Floor Model High Efficiency Gas Pasta Cooker OPERATION L20 393 rev 0 04 12 13 FIGURE 3...

Страница 18: ...ter will lower the pasta s internal temperature and stop the cooking process Rinsing or submerging will also prevent sticking and remove dissolved starch If the appliance is equipped with a rinse tank...

Страница 19: ...ress the ON OFF 1 Button once The Digital Control will display in the display window To toggle between simmer and boil mode simply press the ON OFF 1 button to change modes 2 4 3 TIMER OPERATION Timer...

Страница 20: ...reasing the quantity of water per pound or use of the manual fill option while cooking if equipped The manual fill should be set to a trickle while cooking to allow the water continue boiling When sto...

Страница 21: ...around the appliance for loose parts or accessories that need to be secured or other foreign items ex Aerosol cans that should be removed from the area Check for water leaks around the drain lines an...

Страница 22: ...of once a year by an Authorized Service Technician recommended by Pitco It may be necessary perform this inspection more then once a year 3 3 1 TEMPERATURE PROBE HIGH LIMIT PROBE Verify probes are in...

Страница 23: ...Check for gas leaks Check and clean vent tube on gas valve pressure regulator Check burners clean debris and grease from pilot and pilot orifice tips Check and adjust burner manifold gas pressure to...

Страница 24: ...itch 1 Turn the appliance off 2 Allow the appliance ample time to cool to room temperature 3 Add water to the cook tank as needed 4 Press the high limit reset button 7 See Figure 3 5 The high limit sw...

Страница 25: ...heat High temperature limit s has tripped Allow appliance to cool and reset High temperature limit s 4 4 TROUBLESHOOTING CHART 4 5 CONTROLLER WARNING DISPLAYS If your appliance is equipped with a tem...