background image

TABLE STEAM KETTLE TILTING — ELECTRIC  

SELF CONTAINED 

INSTALLATION 

SPECIFICATIONS

 

 

DIMENSIONS: 

(  ) = Millimeters 

 

EXTERIOR

 

TILT CLEARANCES

 

KETTLE

 

Front

 

MODEL

 

Width

 

A

 

Height

 

B

 

Width 

C

 

Depth 

D

 

Height

 

E

 

F

 

G

 

Raw H

 

Height

 

O.D.  

J

 

I.D.

  

K

 

L

 

M

 

 
 

KTPE-05

 

22.56" 

(573)

 

27" 

(686)

 

22"

 

(559)

 

12" 

(305)

 

1" (25)

 

8.5" 

(216)

 

2.25" 

(57)

 

9" 

(229)

 

6.5" 

(165)

 

13.4" 

(340)

 

12.6" 

(320)

 

11.6" 

(295)

 

21.6" 

(549)

 

 

KTPE-10

 

25.75" 

(654)

 

30" 

(762)

 

22"

 

(559)

 

14" 

(356)

 

1" (25)

 

8.5" 

(216)

 

4.38" 

(111)

 

8.5" 

(216)

 

4.25" 

(108)

 

16.75" 

(426)

 

16" 

(406)

 

14.25" 

(362)

 

25.1 " 

(638)

 

 

 

3/8-16 UNC-2B 

THD MOUNTING 

HOLES

 

 

ELECTRIC

 

CRATE SIZE

 

MODEL

 

POUR 

PATH  

N

 

O

 

P

 

Q

 

R

 

Width

 

Depth

 

Height

 

CUBIC 

VOLUME

 

CRATED 
WEIGHT

 

 
 

KTPE-05

 

12" (305)

 

4" (102)

 

1" (25)

 

3.5" 

(89)

 

2" (51)

 

20" (508)

 

26" (660)

 

25" (635)

 

7.52 cu. ft.  

.21 cu. m.

 

130 lbs. 

58.97 kg.

 

 
 

KTPE-10

 

12" (305)

 

4" (102)

 

1.5" 

(38)

 

3.5" 

(89)

 

2"

 

(51)

 

24" (610)

 

28" (711)

 

29" (737)

 

11.28 cu. ft. 

.32 cu. m.

 

160 lbs. 

72.58 kg.

 

UTILITY INFORMATION: 

ELECTRIC:

 Single electric connection required. 

(For location,

 see 

drawing above.)

 

KTPE-05 0 @ K.W.

 

KTPE-10 

@

 12 K.W.

 

 

Standard: 208/60/1

 

Total Connected Amps - 29

 

 

Standard: 208/60/1

 

Total Connected Amps -

 

 

Optional: 240/60/1

 

Total Connected Amps - 25

 

 

Optional: 240/60/1

 

Total Connected Amps -

 

 

Optional: 208/60/3

 

Total Connected Amps - 25

 

 

Optional: 208/60/3

 

Total Connected Amps -

 

 

Optional: 240/60/3

 

Total Connected Amps - 21

 

 

Optional: 240/60/3

 

Total Connected Amps -

 

 

 

Optional: 480/60/3

 

Total Connected Amps -11

 

 

 

Optional: 480/60/3

 

Total Connected Amps -

 

 

TABLE STEAM KETTLE — ELECTRIC SELF CONTAINED

 

SECTION ONE — INSTALLATION

 

PAGE 1

 

 

 

INSTALLATION

 

Содержание KTPE-05

Страница 1: ...he terms and conditions of the Manufacturer s Limited Warranty will be rendered void and no warranty of any kind shall apply If the equipment has been changed altered modified or repaired by other tha...

Страница 2: ...tant that you read this manual carefully TABLE OF CONTENTS SECTION ONE INSTALLATION Specifications 1 Installation 2 Performance Check 2 SECTION TWO USER S GUIDE Warranty 1 Operation 2 Maintenance 3 SE...

Страница 3: ...1 25 3 5 89 2 51 20 508 26 660 25 635 7 52 cu ft 21 cu m 130 lbs 58 97 kg KTPE 10 12 305 4 102 1 5 38 3 5 89 2 51 24 610 28 711 29 737 11 28 cu ft 32 cu m 160 lbs 72 58 kg UTILITY INFORMATION ELECTRI...

Страница 4: ...either case the proper procedure for KTPE 5 and KTPE 10 would be to remove the plug from the rear of the unit and fill with chemically pure water to the bottom of the plug opening Replace plug secure...

Страница 5: ...l or special damages of any nature that may arise in connection with such product or part Should service be required at times which normally involve overtime or premium labor rates the owner shall be...

Страница 6: ...antage of this low temperature is that most foods won t stick to the sides This transmits into reduced labor costs since most foods do not require constant stirring All equipment must be installed cor...

Страница 7: ...y rubbing the surface with SCOTCH BRITE scouring pads or STAINLESS scouring pads DO NOT USE ORDINARY STEEL WOOL as any particles left on the surface will rust and further spoil the appearance of the f...

Страница 8: ...ce every day Certain foods containing salt vinegar or tomato base additive may cause the inner surface of the kettle to pit The kettle should be thoroughly cleaned after each use when these types of f...

Страница 9: ...A clockwise to decrease pressure 5 Replace knob on dial shaft NOTE Let unit cycle a few times to make sure that the thermostat is working properly PRESSURE SWITCH 1 Disconnect power to unit 2 Tilt ke...

Страница 10: ...st to 50 psi Replace switch if found defective Steam escapes from pressure relief valve Thermostat setting too high Adjust thermostat Replace if found defective With kettle heated to 5 to 10 psi open...

Страница 11: ...SERVICE SERVICE TABLE STEAM KETTLE ELECTRIC SELF CONTAINED SECTION THREE SERVICE PAGE 4 Litho in U S A 6 88...

Страница 12: ...SERVICE SERVICE TABLE STEAM KETTLE ELECTRIC SELF CONTAINED SECTION THREE SERVICE PAGE 5...

Страница 13: ...acement parts may be ordered either through a Southbend Authorized Parts Distributor or a Southbend Authorized Service Agency When ordering parts please supply the Model Number Serial Number Part Numb...

Страница 14: ...8 S S Plug 1167453 PP 515 1 1 1 1 1 1 Pressure Vacuum Gage 1167454 PP 687 1 1 1 1 1 1 Pressure Control 1167455 1166490 PP 688 1 1 1 1 1 1 Chromed Safety Valve 1167456 PP 694 1 1 1 1 1 1 Heating Elemen...

Страница 15: ...919 552 9798 800 348 2558 Convection ovens Cook hold convection ovens Bake roast ovens Pizza ovens Ranges Fryers Special custom equipment Convection steamers Steam kettles Tilting braising pans Cooke...

Страница 16: ...y to extend the useful life of this unit When service is needed contact a Southbend Authorized Service Agency or your dealer To avoid confusion always refer to the model number serial number and type...

Отзывы: