M
ODEL
EZ-3 & EZ-5 C
OUNTERTOP
S
TEAMERS
T
ROUBLESHOOTING
Figure 16
Door Switch Continuity Check (for units built before January 15, 2001)
Terminal Block
Door Switch
Model EZ-3
Model EZ-5
1. Disconnect power at circuit breaker.
2. Remove control panel.
3. Depress and release door switch actuator rod to make sure door switch is properly actuated.
4. EZ-3: Remove door switch lead wires from terminal block positions 2 and 3, or
EZ-5: Remove door switch lead wires from terminal block position 1 and terminal 2 of the controller.
5. Place test lead as shown inside the terminal connectors of the lead wires.
6. Check for continuity - (there should be NO continuity).
7. Depress door switch actuator rod and check for continuity - (there should be continuity).
TROUBLESHOOTING
O
PERATOR
’
S
M
ANUAL
1178387 P
AGE
27