SERVICE CONNECTIONS 

Supply gas through ½ pipe with pressure of apporx. T W.C.  For propane use 11” W.C. pressure.  A gas shut- 

GC- 

Off valve must be installed in supply piping convenient and adjacent to appliance. 

 

 

Unless otherwise specified.  Field Wire Electrical Connection to be 120 Volts, 60 Hertz single phase with grounding 

EC- 

wire. 

Wiring diagram location inside control box. 

WD- 

 

 

DIMENSIONS 

MODEL

 

CAPACITY

 

 

A

 

B

 

C

 

D

 

E

 

F

 

G

 

H

 

BGLT-30

 

30 gallons 

114 liters

 

inches 

mm

 

49.5 

1257

 

35 

889

 

33.5 

85.1

 

24 

61O

 

43.125 

1095

 

37 

540

 

10.5 

267

 

68 

1727

 

BGLT-40

 

40 gallons 752 

liters

 

Inches 

mm

 

58.5 

I486

 

35 

889

 

43.5 

1105

 

24 

610

 

52.125 

1324

 

37 

540

 

10.5 

267

 

68 

1727

 

 

 

-4- 

Содержание BGLT-24

Страница 1: ...then the terms and conditions of the Manufacturer s Limited Warranty will be rendered void and no warranty of any kind shall apply If the equipment has been changed altered modified or repaired by other than a qualified service technician during or after the 12 month limited warranty period then the manufacturer shall not be liable for any incidental or consequential damages to any person or to an...

Страница 2: ...T TO OPERATE THIS UNIT IN THE EVENT OF FAILURE ADEQUATE CLEARANCES MUST BE MAINTAINED FOR SAFE AND OPERATION THE APPLIANCE AREA MUST BE KEPT FREE AND CLEAR OF COMBUSTIBLES DO NOT OBSTRUCT THE FLOW OF COMBUSTION VENTILATION AIR WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH THE INSTAL TION OPERATING AND MAINTENANCE INSTRUCTIONS T...

Страница 3: ... read thoroughly and that all instructions be followed carefully This manual should be retained lor future reference INDEX DESCRIPTION PAGE IMPORTANT NOTES 2 INDEX 3 INSTALLATION AND SERVICE CONNECTIONS 4 5 INSTALLATION INSTRUCTIONS 5 OPERATION INSTRUCTIONS 6 PERIODIC MAINTENANCE 7 ...

Страница 4: ...ise specified Field Wire Electrical Connection to be 120 Volts 60 Hertz single phase with grounding EC wire Wiring diagram location inside control box WD DIMENSIONS MODEL CAPACITY A B C D E F G H BGLT 30 30 gallons 114 liters inches mm 49 5 1257 35 889 33 5 85 1 24 61O 43 125 1095 37 540 10 5 267 68 1727 BGLT 40 40 gallons 752 liters Inches mm 58 5 I486 35 889 43 5 1105 24 610 52 125 1324 37 540 1...

Страница 5: ...st edition In Canada installation must be in accordance with the C S A C22 1 Canadian electrical code part 1 INSTALLATION INSTRUCTIONS 1 Ideally an exhaust system should be located directly above the appliance to exhaust combustion gases generated by the unit 2 Appliance is intended for use on non combustible floors Minimum clearance from combustible and noncombustible floor construction 3 76mm on...

Страница 6: ...hen ignition is complete the flame sensor signials the controller to shut off the glow coil 7 When the skillet has re ched set temperature the pilot lights will go off and the burners will shut off The unit will cycle ON and OFF to maintain set temperature 8 Turn power OFF and thermos tat OFF when skillet not in use Notice If gas supply is interrupted during operation a 5 minute period of complete...

Страница 7: ...nd dry Do not get water in electrical box or any electrical component ADJUSTMENTS WARNING AT LEAST TWICE A YEAR HAVE AN AUTHORIZED SERVICE PERSON CLEAN AND ADJUST THE UNIT FOR MAXIMUM PERFORMANCE All units are adjusted at the factory In case of problems in operation at initial installation check type of gas and manifold pressure and compare it with information on rating plate TROUBLE SHOOTING Burn...

Отзывы: