INSTALLATION INSTRUCTIONS
Electric Counter Tilting Skillet
SET UP
a)
Ascertain correct position of skillet for tilting purposes on working surface. Approximately 30" (761 mm) Co front
of base from wall. Be sure skillet tilts easily.
b)
Secure skillet by bolts -provided Co properly leveled working surface.
1.1
c)
Seal skillet to table top with Silastic or other sealing compound.
SERVICE CONNECTION
a)
All internal wiring of the skillet is complete.
b)
Make a waterproof electrical connection from incoming lines to the control box.
c)
Ground skillet Co terminal provided in control housing.
d)
A wiring diagram is provided inside the control housing cover panel.
e)
All skillets have been factory tested for control and electrical heating elements.
f)
Check for proper operation.
1.2
WIRING DIAGRAM LOCATED INSIDE CONSOLE COVER
2
SECTION: 1