DJUSTMENTS
A
DJUSTMENT OF
O
VEN
P
ILOT AND
B
URNER
The burner orifice is of the fixed type, sized for the type of gas and the operating altitude. To adjust the burner air-gas
mixture, loosen the screw that secures the air shutter on the mixer face and rotate the mixer cap to obtain a clear,
stable blue flame with a distinct inner cone at each port. Excessive primary air causes “blowing” (the flames leaving the
ports), while insufficient primary air causes a soft or yellow tipped flame.
The oven pilot flame is adjusted by using a screwdriver to turn the adjusting screw on the pilot line valve (see drawing
below). The pilot line valve is located behind the kick panel below the oven door. To gain access, lift the kick panel
straight up and pull the top edge out.
Figure 11
UNITS WITH STANDING PILOT
Adjustment Screw for Pilot
Adjustment Screw for Pilot
Air Shutter
Pilot
Pilot
Air Shutter
UNITS WITH ELECTRONIC IGNITION