48
OPERATIONAL STEPS
KEY
DISPLAY
①
Set coordinate values of occupied
point and instrument / prism height
1)
※
Set backsight azimuth
②
。
2)
※
③
Collimate target.
※
3)
Click [Coord]. Measurement
④
ends and the result displays. 4)
※
[Coord]
1)
※
In case the coordinate of occupied point is not entered, then the coordinate of occupied point set
last time would be used. The instrument height and the prism height will be the value you set last time.
2)
※
Refer to Section “6.1.3 Horizontal Angle Reading Setting” or “6.3.2 Setting the Backsight Point”.
3)Click[Mode]
※
,
the mode (SINGLE/N-TIME/REPEAT/TRACKING) changes .
4)
※
To return to the normal angle or distance measuring mode, click [Angle]/ [Dist].
7. APPLICATION PROGRAMS
7.1 LAYOUT
The difference between the measured distance and the preset distance is displayed.
The displayed value = Measured distance – Standard (Preset) distance
●
This function enables the stake-out of Horizontal Distance (HD), Vertical Difference (VD) or
Slope Distance (SD) .
Example
: