South NET S9 Скачать руководство пользователя страница 15

                                                                     

NET S9 user manual

 

12 

 

 

2.2 Battery safety 

NetS9 uses built-in rechargeable Li-ion battery. When using the battery, please note: 

 

Warnings

 

a) If the battery discolors and leaks or has other undesirable phenomena, please do         

not use;         

  b) Do not short circuit the battery, disassemble damaged, approaching heat or throw 

in a fire, avoid direct sunlight; 

 c) Do not put the battery in water. 

 

2.3 Battery charge & usage 

The internal battery will automatically recharge when external power is used. Battery before 

first use, please fully charged. If the battery is placed for three months  without using, first 

fully charged, then use it. It will take about 24 hours for full charge. 

 

Warnings

 

a) Do not charge the damage or leaking battery; 

    b) Do not disassemble the battery and charge alone. 

 

2.4 Conserve battery 

The battery should be fully charged before conservation;   

If long-term conservation, please ensure to charge once every three months. 

Содержание NET S9

Страница 1: ...NET S9 user manual NET S9 User Manual South surveying mapping instrument co ltd 18 06 2014...

Страница 2: ...2 3 Battery charge usage 12 2 4 Conserve battery 12 Chapter3 NetS9 configuration 13 3 1 Keys and LCD configuration 13 3 1 1 Key function 13 3 1 2 LCD interface 14 3 2 The Web Server configuration 16...

Страница 3: ...7 4 3 2 Network settings 41 4 3 3 Reference station setting 42 4 3 4 Data recording setting 43 4 3 5 Data transmission 43 4 3 6 Broadcast SCMRX 44 4 4 NRS normal status 45 4 4 1 Station normal status...

Страница 4: ...h new aluminum alloy design and it can adapt to the complex work environment with Level of IP67 industrial design and fully meet the CORS system unattended for a long time and stable operation of dema...

Страница 5: ...and reduce the costs The receiver has auto restart function which can work continually after blackout without any setting again it has long term and stable capacity of work which can long term contin...

Страница 6: ...Ethernet interface design stronger applicability 10 With 8 GB high speed built in memory stable and reliable eMMC storage method the receiver has the automatic cycle storage function In addition the u...

Страница 7: ...B Unfiltered unsmoothed pseudo range measurements data for low noise low multipath error low time domain correlation and high dynamic response Very low noise of GNSS carrier phase measurement the prec...

Страница 8: ...ment Stable long distance RTK calculating ability Position accuracy static Plane 2 5mm 1x10 6D elevation 5 0mm 1x10 6D RTK Plane 10mm 1x10 6D elevation 20mm 1x10 6D Initialization time Less than 60 se...

Страница 9: ...e 2 RJ45 network interface 2 RS232 interface and support the aerometeograph inclinometer and all kinds of sensors 1 main USB interface external USB storage is used to record the original observation d...

Страница 10: ...sly more than 15 hours after charged Power level 3 8 W Environment Working temperature 40 75 Storage temperature 40 80 1 3 Appearance structure 1 3 1 Appearance Receiver of NetS9 receiver appearance i...

Страница 11: ...NET S9 user manual 8 Fig 1 1 NetS9 1 3 2 Front panel NetS9 front panel is as shown in figure 1 2 it mainly provides buttons and LCD display function Fig 1 2 NetS9 front panel...

Страница 12: ...iption 1 3 button View and modify the receiver configuration 2 LED display Check the working state of the receiver and function configuration 1 3 3 Rear panel NetS9 rear panel provides a more diverse...

Страница 13: ...nterface external events input interface a serial port and power interface 4 RS 232 interface Static data output the output difference data output the navigation data external interface 5 USB interfac...

Страница 14: ...he built in battery Only when the receiver is not connected to an external power supply or external power failure the internal battery will work For a receiver to work properly the external power supp...

Страница 15: ...battery in water 2 3 Battery charge usage The internal battery will automatically recharge when external power is used Battery before first use please fully charged If the battery is placed for three...

Страница 16: ...way to complete NetS9 parameter configuration 3 1 Keys and LCD configuration 3 1 1 Key function NetS9 front panel is as shown in figure 1 2 a total of eight buttons Users can use these buttons to swi...

Страница 17: ...click this key Users can access to the parameters of the interface for base station to launch coordinate system and modifications of different schemes The parameters of base station are as shown in fi...

Страница 18: ...you can press the buttons to change the location of the cursor the button to modify the size of the parameter values When these parameters all are changed if you press the button it will save the data...

Страница 19: ...he button If without operating for a long time the instrument will automatically closed LCD screen and you can press any key to wake it up 3 2 The Web Server configuration When you enter the IP addres...

Страница 20: ...provides the help shortcut keys if the user cannot login system or the system page is abnormal they are available by clicking on the login page in the top right corner of the help to get the solution...

Страница 21: ...management and help Check the function as shown in table 3 2 number menu Function introduction 1 Status Provides information working status and positioning information of receiver system 2 configurat...

Страница 22: ...eiver network parameters and WiFi Settings 7 Firmware update Receiver firmware upgrade 8 User management Increase and manage the Web Server user 9 Help Get the solution Tab 3 2 the main functions of e...

Страница 23: ...cation information satellite status and PDOP value 2 The configuration menu The configuration menu is as shown in figure 3 8 Users can set the various parameters of the NetS9 through the receiver conf...

Страница 24: ...onfig interface a Base setup interface is as shown in figure 3 7 Users can complete basic settings such as base station coordinates and differential format etc Users not only can input the precise coo...

Страница 25: ...tup interfaces is as shown in figure 3 8 Users can choose different measuring methods for antenna height Fig 3 8 the interface of antenna setup c The satellite tracking interface is as shown in figure...

Страница 26: ...ce is as shown in figure 3 10 Fig 3 10 receiver operate interface e Default language interface here users can choose Chinese or English as display language B Satellite information interface is as show...

Страница 27: ...vailable or not Fig 3 11 satellite information interface C Data record is as shown in figure 3 12 The user can set the data storage format storage method file interval point name epoch interval etc al...

Страница 28: ...anual 25 Fig 3 12 data record interface Fig 3 13 data download interface D Data transfer interface is as shown in figure 3 14 Set to transmit the raw data and differential SCMRX to the indicated IP PO...

Страница 29: ...Lemo port serial port bluetooth port raw data port and differential port display here if there is a serial port being occupied and then the status menu will become green as shown in figure 3 16 Fig 3...

Страница 30: ...l port config interface c TCP IP config interface is as shown in figure 3 17 Select the needed work mode and data flow set the ip and port which matched with server and enable it Figure 3 17 TCP IP co...

Страница 31: ...interface is as shown in figure 3 19 Here in navigation data interface you can set the NMEA 0183 data output frequency in SIC navigation data you can disable enable the data output in raw observation...

Страница 32: ...s shown in figure 3 20 Including Ethernet config WIFI config and Bluetooth config Fig 3 20 network config interface a Ethernet Settings interface is as shown in figure 3 20 Users select no automatical...

Страница 33: ...ost name AP_Password is the password for connecting to the host and you do not need a password to login when the AP is not encrypted Fig 3 21 WIFI config interface F Firmware update interface is as sh...

Страница 34: ...terface is as shown in figure 3 23 It is used for adding and managing account Only the administrator can change any parameters of the receiver and manage users and ordinary users can only view the rec...

Страница 35: ...server they need to map the LAN 80 port of NetS9 to WAN port Assuming that the port 80 is mapped to port 8000 users only need to input public IP and port into the local browser eg if the receiver pub...

Страница 36: ...pter4 NETS9 single station configuration 4 1 NRS Station setup 4 1 1 Add new stations Add a new station Fig 4 1 new station Follow the Figure 4 2 to complete the station configurations Fig 4 2 station...

Страница 37: ...ntenna type selection 5 Parameter Coordinate input must be XYZ or BLH 6 Fixed Select it as a fixed base coordinate 7 Add Add a new station 8 Delete Delete station 9 Backup Backup stations in case you...

Страница 38: ...nd NRS server are installed in same PC the inner IP should be 127 0 0 1 2 Differential type Standard differential options 3 File save setting setup the static data format and the storage format also t...

Страница 39: ...station software The PORT1 should be same with the PORT you set in NRS station services setup eagle server as Figure 4 4 item 1 Eaglenet IP PORT is for network CORS and the inner IP is 127 0 0 1 the P...

Страница 40: ...lso automatically obtain IP address but for the convenience of explanation here server PC IP address is 192 168 6 6 NET S9 connect to server PC through router the NET S9 IP is 192 168 6 10 Fig 4 6 NET...

Страница 41: ...NET S9 user manual 38 Fig 4 7 LAN setting WAN setting should be set according to the parameters which supplied by the carrier as Figure 4 8 Fig 4 8 WAN setting...

Страница 42: ...arameters like above Figure and the DNS server IP should be according to the one which provided by carrier 3 Configure NETS9 via WIFI NETS9 has WIFI hotspot while your PC mobile and tablet can connect...

Страница 43: ...default is no restriction for access Computer tablet or smart phones and other terminals can be connected directly to galaxy hotspot without password Fig 4 11 NETS9 default SSID Input 10 1 1 1 into b...

Страница 44: ...er manual 41 Login Username admin password admin Fig 4 12 NETS9 login interface 4 3 2 Network settings Set the network parameters after login the web server interface Fig 4 13 NETS9 network parameters...

Страница 45: ...4 3 3 Reference station setting Fig 4 14 reference station settings Only base station coordinate need to be edited the other settings can be kept default Submit all settings when done Fig 4 15 antenn...

Страница 46: ...d Fig 4 16 data recording setting 4 3 5 Data transmission Mode should be set to client mode which means here the receiver provides the raw data And the raw data should be sent out with an indicated IP...

Страница 47: ...oadcast SCMRX Fig 4 18 scmrx transmission setting S9 can create scmrx with BDS directly which no need to be processed so that it can be sent to eagleserver directly Eagleserver can broadcast this corr...

Страница 48: ...5 The caster address should be the IP where the eagleserver is installed and the PORT should be the same as your eagleserver PORT See Figure 4 18 4 4 NRS normal status 4 4 1 Station normal status Fig...

Страница 49: ...lity that can map the port The procedure is making the sever LAN IP PORT to the WAN IP PORT so that the users can access even if it is in a different network area The function is also called NAT netwo...

Страница 50: ...on Server Port The port you need map 6060 IP Local server IP 192 168 6 6 The other settings keep default After completing the port mapping type the WAN IP PORT eg 58 248 35 130 6060 into browser it me...

Страница 51: ...and 45 The device complies with RF specifications when the device used at 20cm from your body Adapter shall be installed near the equipment and shall be easily accessible The plug considered as disco...

Страница 52: ...ot installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installa...

Отзывы: