FPS-650 and FPS-1250 South-Tek Systems
Version:
7
Revision Date: 9/6/19
Page 8 of 29
Safety Relief Valves:
Safety Relief Valves have been placed throughout the system for maximum
safety. They are designed and put in place to minimize failure of other
components. They all come with an ASME stamp.
N2 Storage Tank:
A N2 Storage Tank is housed inside the cabinet with manual ball valves and
gauge. It is plumbed to an external manual ball valve so that the end-user will
not have to do any plumbing within the cabinet.
Automatic Cut-In/Out:
The generator comes with a built-in pressure switch that is tied into the PLC.
This will provide a low voltage signal back to the PLC to put the system in a
“Standby Mode” when the tank is full of Nitrogen.
Patented Blast-Off Detection (optional):
The Blast-Off Leak Detection will provide the end-user with an alarm when it
detects characteristics of a leak somewhere on the system. It will trigger an
audible alarm, display it on the screen, and the end-user can tie into the dry
contact so that the alarm can be relayed back to the Building Management
System (BMS).
SPECIFICATIONS
Table 1: Specification Data
N2-Blast® FPS-650 and FPS-1250
–
Specifications
Nitrogen Purity
98.0+%
Installation
Wall Mount (FPS-650) / Floor standing (FPS-1250)
Display
Run Hours / Run Status / Alarm Status
N
₂
Storage Pressure
55-75 PSIG
Cabinet Port
Connections
1/2" NPT Female
Electrical
110-240V / 50-60Hz / 1Phase; 20 Amp Breaker
Compressor
Integral / Oil-Free
Ambient Temperature
40° to 90°F
Noise Level (dbA)
< 75 dBa (Nitrogen Generator)
Size
12.68” W x 10” D x 29.5” H (FPS-650 Cabinet Dimensions)
26" W x 18" D x 59" H (FPS-1250 Cabinet Dimensions)
15.1” OD x 50” H (100# Tank for FPS-650 Only)
Weight
Appx: 84 lbs (FPS-650)
Appx: 265 lbs (FPS-1250)
Appx: 75 lbs (100# Tank)