SA252
Atlas Compressor User Guide
14
Recalling Presets
The first six User Presets are accessible via the onboard hardware or with an external footswitch in
the following ways:
1.
Move the toggle switch to left, center, or right to access presets #1-3.
2.
Press the ALT button while moving the toggle switch to access presets #4-6, or press + hold the
footswitch when the pedal is OFF for 5 seconds to access the Red LED (presets #4-6).
Recalling MIDI Presets
All 128 available User Presets are accessible with an external MIDI controller. MIDI controllers can be
connected via USB port at the top of the pedal, or through a Neuro Hub, which connected to the
CONTROL INPUT at the top of the pedal. All 128 User Presets can be recalled with the corresponding
MIDI program change (PC) messages.
Note:
When recalling presets via MIDI PC messages, you may wish to queue up your preset with
effect bypassed. To do this, simply engage the preset, bypass it with the footswitch, then re-save the
preset normally. When recalled, the pedal will load the saved user settings, but the effects will be
bypassed until you engage the pedal.
Copying a Preset to a New Location Using the Neuro App
Using the BURN and SAVE AS commands in Neuro Mobile or Desktop Editors, it is possible to copy
presets to any location in memory.
Clearing all Presets
All 128 User Presets can be erased using the Factory Reset procedure. Warning: The Factory Reset
procedure resets the entire pedal back to the state in which it was originally shipped – this includes all
global settings and User Presets. A Factory Reset will not erase any firmware updates.
*
*
*
External Control Options
There are two main ways the Atlas’s Control Input port is utilized. Below are the possible used for
the Control Input port. Please note that External Switch Options is a global hardware setting.