3. Mechanically moved parts like axles, eyes and others must not show any
traces of wearing (e.g. material abrading or damages) and must not rerate
with unbalances.
4. The electric power supply cables must not show any damages, material fa-
tigue (e.g. porous cables) or sediments. Further instructions depending on
the installation spot and usage have to be adhered by a skilled installer and
any safety problems have to be removed.
Danger! High power! Danger to life!
Disconnect from mains before starting maintenance operation!
We recommend a frequent cleaning of the device. Please use moist flax to
clean. Never use alcohol or solvents.
CAUTION! The lens has to be replaced when it is obviously dama-
ged, so that its function is impaired, e.g. due to cracks or deep scra-
tches!
The objective lens will require weekly cleaning as smoke fluid tends to building
up residues, reducing the light-output very quickly. The cooling-fans should be
cleaned monthly.
The gobos may be cleaned with a soft brash. The interior of the fixture should
be cleaned at least annually using a vacuum cleaner or an air-jet.
The dichroic color filters, the gobo-wheel and the internal lenses should be
cleaned monthly.
To ensure a proper function of the gobo-wheel, we recommend lubrication in
six-month intervals. The quantity of oil must not be excessive in order to avoid
that oil runs out when the gobo-wheel rotates.
There are no serviceable parts inside the device except for the lamp and the
fuse. Maintenance and service operations are only to be carried out by autho-
rized dealers. Please refer to the “inserting and exchanging lamp” chapter in
this manual.
7.1. REPLACING THE FUSE
If the lamp burns out, the fine-wire fuse of the device might fuse, too. Only re-
place th fuse of same trpe and rating. Before replacing the fuse, unplug mains
lead.
Procedure: