Soundoff Signal nFUSE Скачать руководство пользователя страница 14

nFUSE™ LED Lightbar

nFUSE Lightbar English  0520

14.

PHOTO SENSOR

The photo sensor continuously monitors ambient light conditions and will control functions configured for operation with the photo sensor input.  By default, the 
photo sensor will (SET) all light modules into low power mode when dark ambient light levels below 50 lux are detected for more than 5 seconds.  When ambient 
light levels exceed 300 lux for 5 seconds, the low power mode will (CLEAR) turn off and the lightbar will revert back to full intensity.

The photo sensor is subject to ambient light conditions of the specific environment for the vehicle and needs to be thoroughly tested by the installer to ensure 
proper light levels and delay are selected to provide the most effective operation in different lighting conditions.

The photo sensor detects ambient light levels, so parking the vehicle under a bright street light during night-time use may (CLEAR) turn off the photo sensor input.  
Likewise, driving though a dark tunnel during daytime use may (SET) the photo sensor input.  Ensure the operator of the vehicle is aware of such possible
conditions and provide additional controls to the breakout box to allow the operator the ability to manually over-ride the
functions when required.

Changing the ambient light SET/CLEAR levels may be modified by updating the setting in the 'Photo Sensor' tab in the PC Application.

The photo sensor controls may be updated by using the PC App.  Refer to the PC App instructions for more detail.

PHOTO SENSOR OVER-RIDE CONFIGURATION INSTRUCTIONS

1.  Click on ‘Breakout Box Inputs’ tab and click on ‘P1:  Photo Sensor’ and note priority and which functions are activated when the photo sensor is active.

NOTICE: 

Installers and users must comply with all applicable federal, state and local laws regarding use and installation of warning devices.

Improper use or installation may void warranty coverage.

To review our Limited Warranty Statement & Return Policy for this or any SoundOff Signal product, visit our website at 

www.soundoffsignal.com/tech-services/returns/

.

If you have questions regarding this product, contact 

Technical Services

, Monday - Friday, 8 a.m. to 5 p.m. ET at 

1.800.338.7337

 (press #4).

  Questions or comments that do not require immediate attention may be emailed to 

[email protected].

ENHANCING SAFETY THROUGH INNOVATION

Содержание nFUSE

Страница 1: ...t is the operator s responsibility to proceed safely The effectiveness of the lightbar is highly dependant on the correct mounting and wiring The installer must read and follow the manufacturer s inst...

Страница 2: ...0AWG Wires Red and Black 22AWG Data Green 25ft 10AWG Wires Red and Black 22AWG Data Green MATERIAL Aluminum Base polycarbonate outer lenses ASA PC top cover STANDBY CURRENT Per Module IGNITION ON 0 20...

Страница 3: ...EW NOTICE Installers and users must comply with all applicable federal state and local laws regarding use and installation of warning devices Improper use or installation may void warranty coverage To...

Страница 4: ...g locations the torque levels for connecting hooks to the lightbar foot may be different based on the vehicle A Minimum requirement for torque should be 10 IN LB with a maximum level of 45 IN LB B Whe...

Страница 5: ...ng surface spaced evenly for securing the lightbar 5 Place the plas c spacer over each moun ng hole 6 Place lightbar and bracket assembly into the holes and install the at washer lock washer and hex...

Страница 6: ...lock nuts to 40 60 in lbs DO NOT OVER TIGHTEN 3 Install the two rubber bumpers on the bracket rotate to lock into posi on 4 Mark the two inner holes on each bracket to drill into the moun ng surface 5...

Страница 7: ...lation may void warranty coverage To review our Limited Warranty Statement Return Policy for this or any SoundOff Signal product visit our website at www soundoffsignal com tech services returns If yo...

Страница 8: ...ing any wires to the battery b DO NOT USE CIRCUIT BREAKER OR FUSIBLE LINK 3 Connect the other end of the Fuse to the POSITIVE terminal of the battery a Do NOT use any more than 2ft of wire between the...

Страница 9: ...o 1 Alternating 350 5 8 SN11 Inter Cycle No No No 1 Alternating SN12 Warp 1 2 3 No No No 1 Alternating SC13 E Single Yes Yes No 1 Alternating 125 2 1 SC14 E Double Yes Yes No 1 Alternating 125 2 1 SC1...

Страница 10: ...C6 Double Dual Yes No No 1 2 Alternating 115 1 9 DC7 Power Pulse Dual Yes No No 1 2 Alternating 180 3 DC8 Road Runner Dual Yes No Yes 1 2 Alternating 115 1 9 DC9 Slow Runner Dual Yes No Yes 1 2 Altern...

Страница 11: ...weep Dual No No No 1 2 DN39 Full Sweep Slow Dual No No No 1 2 DN40 Center Sweep Dual No No No 1 2 DN41 Center Sweep Slow Dual No No No 1 2 DN42 Orbit Dual No No No 1 2 DN43 Orbit Slow Dual No No No 1...

Страница 12: ...Work lights c Apply voltage to the Takedown activation wire d Apply voltage to the light group wire s required i e Front Inboard 1 Rear Inboard 2 etc e Momentarily apply voltage to the pattern select...

Страница 13: ...Cruise Mode Configuration a Apply voltage to Ignition Input Wire and then set Switch 2 on Breakout box to down position Switch 1 must be in Up position b Determine which module inputs are needed for...

Страница 14: ...the vehicle is aware of such possible conditions and provide additional controls to the breakout box to allow the operator the ability to manually over ride the functions when required Changing the a...

Страница 15: ...off even if the photo sensor is active since the gray wire control is a higher priority than the photo sensor control NOTICE Installers and users must comply with all applicable federal state and loca...

Страница 16: ...een PIN 13 Blue Pink White PIN 12 Purple White PIN 11 Gray White PIN 10 Black White PIN 9 White PIN 8 Purple PIN 7 Brown White PIN 6 Light Green PIN 5 Black PIN 4 Gray PIN 3 Green White PIN 2 Blue Whi...

Страница 17: ...CNR ALS ID60 ALS ID 60 FCNR FINB1 FINB2 FINB3 FINB2 FINB1 FCNR RCNR RINB1 RINB2 RINB3 RINB2 RINB1 RCNR ALLEY ID30 ID15 ALLEY 42 LIGHTBAR ID13 ID14 ID29 ID16 ID2 ID3 ID4 ID12 ID28 ID27 ID26 ID18 ID17 I...

Страница 18: ...B3 FINB4 FINB4 FINB3 FINB2 FINB1 FCNR ALLEY ID30 ID15 ALLEY 60 LIGHTBAR RCNR RINB1 RINB2 RINB3 RINB4 FRNB4 RINB3 RINB2 RINB1 RCNR ALS ID60 ALS ID 60 FCNR FINB1 FINB2 FINB3 FINB5 FINB4 FINB4 FINB3 FINB...

Страница 19: ...crews 3 Disconnect all wire harness connectors attached to the board 4 Remove power distribution driver module sensor board 5 Snap new distribution photo sensor board assembly into housing 6 Reconnect...

Страница 20: ...ED s operating correctly Verify configuration and make sure light modules are configured for takedown function No steady Red LED on breakout box Check 24 pin connector at breakout box insure it is sna...

Страница 21: ...bar English 0520 21 CONNECTION OF LIGHTBAR BREAKOUT BOX TO SOUNDOFF SIGNAL SIREN Note Requires PC configuration app to map siren control switches to lightbar functions Plug 1 end of RJ 45 cable to ava...

Страница 22: ...D1 DIVIDER 8 PNULBTCSKT1 SINGLE DOME REPLACEMENT HARDWARE KIT 9 PNULBSN0000 BLANK MODULE BRACKET 10 PNULBBEC1 END BASE 11 PNULBBC06 INBOARD BASE PNFLBK01 FIXED HEIGHT PERMANENT MOUNT EA PNFLBK02 HEADA...

Страница 23: ...l number E mail address where RMA should be e mailed Fax number where RMA should be faxed RMA will not be given without this information If available please provide this information SoundOff Signal wi...

Отзывы: