EVCS_Remote  Node_ENGND04101  1.15       

1.800.338.7337 / www.soundoffsignal.com

NOTICE: 

Installers and users must comply with all applicable federal, state and local laws regarding use and installation of warning devices.

Improper use or installation may void warranty coverage. To review our Limited Warranty Statement & Return Policy for this or any SoundOff Signal product, visit our website at

www.soundoffsignal.com/sales-support

. If you have questions regarding this product, contact 

Technical Services

, Monday - Friday, 8 a.m. to 5 p.m. at 

1.800338.7337

 (press #4 to skip the

automated message). Questions or comments that do not require immediate attention may be emailed to 

[email protected].

SUPERIOR CUSTOMER RELATIONSHIPS. SMARTLY DESIGNED LIGHTING & ELECTRONIC SOLUTIONS.

3

Wiring and Interconnect Requirements for ENGND04101 Remote Node

•High current interconnects require careful termination with the proper equipment. 

 WARNING! Poor crimp quality can cause significant heat build-up and fire.

 Follow connector

   manufacturer instructions to terminate properly.

•Remote Node can switch up to a 

total maximum of 50Amps.

  User must configure outputs to not exceed this total current.  Individual output switches are rated up to 10Amps each for higher  

  current loads, 

but the total device current must not exceed 50Amps.

  The software warns when these limits are exceeded and user must ensure that individual output limits and total device   

  current limits are not exceeded in normal use.

Do not gang or parallel multiple outputs to drive a high current load. 

 Multiple 5Amp and 10Amp outputs must not be combined to achieve a higher current limit.  

TERMINATION OPTION 2

Purchase individual connector components to terminate the wires at the connector.

Molex P/N:

 19418-0030

Molex P/N:

 19420-0001

Molex P/N: 

19417-0119

MX150L™ 16 Circuit Sealed
Receptacle for 14-16 AWG Wire

MX150L™ Female Terminal for 14-16 AWG 
Wire, Tin Plated

MX150L™ Socket Plug/Key (One plug re-
quired for each unused pin location to seal)

•MX150L Assembly Instructions: http://www.molex.com/pdm_docs/as/AS-19417-001.pdf

•Application Tooling Specification Sheet: http://www.molex.com/pdm_docs/ats/ATS-6381144HM.pdf

•Quality Crimping Handbook: http://www.molex.com/pdm_docs/ats/TM-638000029.pdf

•Actual terminal and housings may be different depending on application, wire type, etc.

Hand Crimp Tool: 

Molex P/N:

  63811-4400

•Manual Extraction Tool: 

 Molex P/N:

  63813-1500

•WARNING! Wire diameter with insulation must be 0.113in to 0.139in (2.87mm-3.53mm) to properly seal

 

(such as SXL 16AWG)

Pros:

•Consistent wire colors, clean install without butt-splices

Cons:

•Need to purchase crimper and train personnel

WARNING

TERMINATION OPTION 1

Purchase accessory mating harness from SoundOff Signal

SoundOff P/N:

 ENGHNK02 (16pin Mating Harness)

Typically a water tight butt--splice with glue is used to   

   protect this termination and is required for exterior use.

Pros:

No need to terminate at the connector pins

•No need to purchase Molex crimper

Cons:

•Requires butt-splice or alternate connector
•Requires heat shrink tubing with glue for exterior

Strip to this length

(drawn to scale)

0.165” to 0.197”

Insulation

Crimp

0.006” to

0.026”