background image

Page 9

For Technical Support - Please Call 1-800-338-7337

or visit

www.soundoffsignal.com

500 Series Control System and Siren Amplifier

ENGSA5(xxxSx)

Rev. D - 07/2021

1

1

1

1

5

5

5

4

4

4

8

8

8

3

1

Main Power Input - Pass through to internal power lug*

75A Max

* Connec�on is on the inside of the amplifier. See page 3 for more detail

*** Relay input is selectable between internal power and external source. See page 4
for more details.

** If running a posi�ve horn ring signal with more than 5A of draw, we recommend an
external horn ring transfer relay. See pages 4 and 11 for more informa�on.

† Connector terminals were changed from �n to gold at Jxxxxx. Do not mix alloy types.

**** Relay input is selectable between internal power and external source. See page 4
for more details.

1

Blue

Relay Slide 1

20A

2

Green

Relay Slide 2

20A

3

Yellow

Relay Slide 3

20A

1

Green / Black

Relay 3 - Ext. - Horn Ring Output**

5A

2

Green / White

Relay 3 - Ext. - Horn Ring Input**

5A

3

Green

Lightbar Bus Channel 2 - Internal B.O.B.

-

4

White

Output 15

5A

5

Blue

Output 11

(Diode Isolated)

5A

6

Brown

Output 12

(Inrush)

10A

7

Yellow

Output 13

5A

8

Orange

Output 14

10A

1

Green / Black

Relay 1 - Normally Open

10A

2

Green / White

Relay 1 - Normally Closed

10A

3

Green

Relay 1 - External Input***

10A

4

White

Output 5

5A

5

Blue

Output 1

(Diode Isolated)

5A

6

Brown

Output 2

(Inrush)

10A

7

Yellow

Output 3

5A

8

Orange

Output 4

10A

1

Green / Black

Relay 2 - Normally Open

10A

2

Green / White

Relay 2 - Normally Closed

10A

3

Green

Relay 2 - External Input****

10A

4

White

Output 10

5A

5

Blue

Output 6

(Diode Isolated)

5A

6

Brown

Output 7

(Inrush)

10A

7

Yellow

Output 8

5A

8

Orange

Output 9

10A

1

RJ-45

Lightbar Bus Channel 1 - Internal or External B.O.B.

C

N

1

C

N

2

C

N

3

C

N

4

C

N

6

C

N

5

S

CHEMATICS

= Diode Isolated

= Inrush

Содержание Blueprint 500 Series

Страница 1: ...perly fused at power source Install protective grommets when routing wire through firewall or metal TABLE OF CONTENTS Introduction 2 Siren System Notice 2 Caution Notice to the Installer 2 Instruction...

Страница 2: ...rator should routinely verify that the siren system is securely fastened to the vehicle and properly functioning Effective sirens generate loud sound pressure levels that can potentially cause hearing...

Страница 3: ...ipment into the aftermarket console For best results use equipment specific brackets or faceplates POWER FUSING Main Power Fusing WARNING TO AVOID DAMAGE OR INJURY DO NOT CONNECT POWER WHEN CIRCUIT IS...

Страница 4: ...ring shutdown of the circuit This is shown on page 14 This diode should be rated at a minimum of 100v at 1a CN4 CN5 CN6 Solid State Programmable Outputs Connectors CN4 CN5 and CN6 have five solid stat...

Страница 5: ...witches are not the same thing as a parallel splitter and will cause data transmission problems CN11 RJ 45 Control Panel Databus Connectivity See the data bus connectivity schematic on page 12 CONTROL...

Страница 6: ...re placing the vehicle into service Volume can be set through the SoundOff Central bluePRINT Software PA Microphone The PA Microphone in bluePRINT is a specialized high gain microphone that connects v...

Страница 7: ...w 1 Red 2 Greens Output Board Voltage High 2 Reds 1 Green Comm Fault USB Port 2 Reds 2 Greens Comm Fault CAN Port 3 Reds 2 Greens Comm Fault Console Control Panel Port 2 Reds 4 Greens Comm Fault Outpu...

Страница 8: ...Specification https bit ly 3a54fEy Connectors CN4 CN5 CN6 Connector Housing Molex 3901 2080 Pins Molex 45750 3111 Fits 5A or 10A Outputs 16 AWG Pin Crimp Tool Molex 200218 2200 Extraction Tool Molex 1...

Страница 9: ...ls 1 Blue Relay Slide 1 20A 2 Green Relay Slide 2 20A 3 Yellow Relay Slide 3 20A 1 Green Black Relay 3 Ext Horn Ring Output 5A 2 Green White Relay 3 Ext Horn Ring Input 5A 3 Green Lightbar Bus Channel...

Страница 10: ...Blue Red CAN A 3 Blue Radio Rebroadcast External PA Input 1 4 Light Blue Black CAN Shield 5 Light Blue White CAN A 6 Blue Radio Rebroadcast External PA Input 2 1 Orange Speaker A Out 2 Orange Black S...

Страница 11: ...points as shown below Input Nodes are only necessary when using additional discrete inputs beyond the eight provided inputs from the 500 Series Control System A lightbar breakout box can be configured...