background image

 

SCD1990SW

 / English Instruction Manual

 

 

2

 

INSTALLATION 

• 

Select a suitable location for the device, such as a dry, flat, non-slip surface on which it is 
easy to operate the machine. 

• 

Ensure that the device is sufficiently ventilated. 

• 

Remove the protective film from the display if it is still present. 

• 

Press the 

“STANDBY / FUNCTION” button to turn on the device. 

• 

Press the 

“STANDBY / FUNCTION” button for approx. 3 seconds to switch into the standby 

mode. 

 

Power Supply 

• 

Ensure that the voltage is the same as that indicated on the model identification plate. 

• 

Connect the power cable supplied (see battery compartment if necessary) to a properly 
installed safety power socket and the mains connector AC on the back of the machine. 

 

Inserting the Batteries 

(not supplied) 

1.  Open the lid of the battery compartment. 
2.  Insert 6 batteries of type UM-2 (

“C” size) 1.5 V. Please ensure that the polarity is correct (see 

the floor of the battery compartment)! 

3.  Then close the battery lid. 

 

NOTE: 

When a mains cable is connected the batteries are automatically switched off. 

After about 10 minute without a signal, the device will automatically switch to standby. 

 

SETTING CLOCK AND DATE 

The system must be in standby mode in order to set the clock. 

1.  Press and hold the 

“ENTER / PLAY / PAUSE / CLOCK” button for approx.2 seconds.  

2. 

Use the “SKIP+ / ” & “SKIP- / TUNING-” buttons to set the time format “12 / 24hr”. 

3.  Press the 

“ENTER / PLAY / PAUSE / CLOCK” button to confirm time format. 

4. 

Use the “SKIP+ / ” & “SKIP- / TUNING-” buttons to set the hours accordingly. The 
hour digits start flashing. 

5.  Press the 

“ENTER / PLAY / PAUSE / CLOCK” button to confirm the hour.  

6.  Repeat step 4 and 5 to set the minute / date. 

 

NOTE: 

Press and hold the “ENTER / PLAY / PAUSE / CLOCK” button during operation order to briefly 
display the current time. 

 

ALARM 

Setting of the alarm time                                                          

The system must be in standby mode in order to set the alarm. 

You have the option of setting two alarm times. Proceed as follows:  

1. 

Press the “VOLUME- / ALARM 1” button for about 3 seconds. The hours of the currently set 
alarm time will start to flash. 

2.  Perform the settings with the 

“SKIP+ / ” & “SKIP- / TUNING-” buttons. 

3.  Press the 

“VOLUME- / ALARM 1” button to confirm. The minutes will start to flash. 

4. 

Perform the settings with “SKIP+ / ” & “SKIP- / TUNING-” button. 

Содержание SCD1990SW

Страница 1: ...NEDERLANDS ENGLISH ITALIANO FRAN AIS ESPANOL SCD1990SW Hersteller W rlein GmbH Tel 49 9103 71670 Gewerbestrasse 12 Fax 49 9103 716712 D 90556 Cadolzburg Email info woerlein com GERMANY Web www woerle...

Страница 2: ...ame or equivalent type CAUTION INVISIBLE LASER RADIATION WHEN OPENING THE COVER OR PRESSING THE SAFETY INTERLOCK AVOID EXPOSURE TO THE LASER BEAM To prevent possible hearing damage do not listen at hi...

Страница 3: ...LAY PAUSE CLOCK button 9 SKIP TUNING button 3 STOP MENU button 10 SKIP TUNING button 4 PRE FOLDER button 11 INFO button 5 VOLUME ALARM 1 button 12 VOLUME ALARM 2 button 6 DISPLAY 13 STANDBY FUNCTION b...

Страница 4: ...matically switched off After about 10 minute without a signal the device will automatically switch to standby SETTING CLOCK AND DATE The system must be in standby mode in order to set the clock 1 Pres...

Страница 5: ...will sound when reaching the alarm time 6 Finally press the SKIP TUNING SKIP TUNING buttons to set the alarm volume Press the VOLUME ALARM 1 to confirm To set the second alarm time repeat each of the...

Страница 6: ...re listening to a radio station in a relatively loud environment By increasing the volume you can play the quiet sections louder This however has the disadvantage that the loud sections become uncomfo...

Страница 7: ...y next radio station Preset station 1 Press and hold the AMS MODE button on unit for about 2 3 seconds to start the automatic preset process 2 Display will show the memory sequence number and radio st...

Страница 8: ...allow us to guarantee full compatibility with all USB storage devices For this reason in rare cases there may be problems in playing back files from USB storage devices This is not a malfunction of th...

Страница 9: ...ously The display will show Repeat One Press three times the whole CD is played continuously The display will show Repeat All Press four times all tracks will be played in random order The display wil...

Страница 10: ...P3 format The device also supports all standard CD types CD CD RW CD R This machine of is able to play MP3 CDs Up to 99 track scan be compressed and stored on these CDs Your machine detects an MP3 CD...

Страница 11: ...Stations 20 DAB 20 FM Audio power output 2x 2W RMS IMPORTER W rlein GmbH Tel 49 9103 71 67 0 Gewerbestrasse 12 Fax 49 9103 71 67 12 D 90556 Cadolzburg Email service woerlein com Germany Web www woerl...

Страница 12: ...3 71 67 0 Con la presente W rlein GmbH dichiara che questo dispositivo conforme ai requisiti essenziali e altre disposizioni contenute nella Direttiva 2014 53 EU Una copia della Dichiarazione di confo...

Отзывы: