background image

A maximum of 5 Outreach Plates can be used with 
the i-ceilings ampli

fi

 ed Sound Panel or IRX Wallmount 

Ampli

fi

 er. The APA/APL (supplied with the packs) is 

intended to be used for the connection of a laptop, 
CD, MP3 player (or similar audio signal) and should be 
located in a convenient position near to the teaching 
position.
Outreach Plates are active with balanced outputs 
and, as such, can be daisy-chained together to 
provide multiple inputs as required, each with its own 
dedicated volume control. By this means it is possible 
to provide a 

fl

 exible input structure to cater for almost 

any conceivable requirement.

Low Level Output Plates (APA/LLO):

These optional units are intended to facilitate the 
connection of individual hearing assistance systems 
to the Sound

fi

 eld system. The plate is supplied with 

a 3.5mm 2pole jack socket with an output level of 
775volts nominal, set by means of a user adjustable 
level control. 
Cable requirements are as Outreach input plates, but 
a separate cable 

must

 be provided where this facility 

is installed.

All Outreach input and output plates require a single gang 
socket box with a minimum depth of 25mm.

 

Outreach Input Plates

Outreach Plate connection cable specification:

The cable between the speaker panel, the 

fi

 rst and any following Outreach Plates 

must be to the following minimum 

specification:

 1 pair twisted and screened for audio, plus 1 additional pair for power. ‘West Penn’ 357 supplied by 

CIE-Group, or any good quality quad microphone cable should be suitable. 
A wide range of Outreach Plates to suit various other interface requirements is available; please call CIE-Group 
for details.

• APA/APL 

Outreach Plate 

  for AV inputs

• APA/LLO Outreach Plate for 
  assistive hearing systems

6

Содержание i-ceilings Pack B

Страница 1: ...www soundfield uk com SYSTEM INSTALLATION GUIDE...

Страница 2: ...and so large non reflective surfaces light absorbent surfaces such as black dark painted walls or large fabric coverage etc in the classroom which may reduce coverage must always be considered in the...

Страница 3: ...ies for IWM 402 2 x Instructions Installation and Operation Manuals Pack F 4 x FBT Project 315 Wallmount Loudspeakers 1 x IRX Wallmount Amplifier IR Receiver 4 x 03284 Safety Cable 1 x IWM 402 Pendant...

Страница 4: ...ble 10 10 Metre IR Sensor Extension Lead IWH 401 Handheld Transmitter Microphone 7W1B2V4 Rechargeable Battery for IWH 301A APA APL CD MP3 Laptop Wall Plate APA LLO Radio Assisted Hearing Aid Output Pl...

Страница 5: ...ower Requirements Pack A B and C Systems A single 13 amp power point is all that is required as all ancillary Soundfield system items are powered directly from the panel amplifier If two speakers are...

Страница 6: ...dfield system The plate is supplied with a 3 5mm 2pole jack socket with an output level of 775volts nominal set by means of a user adjustable level control Cable requirements are as Outreach input pla...

Страница 7: ...the centre of the wall behind the teaching position and the same position on the opposite wall will give the best coverage see Diagram1 above alternatively position on opposite sides of the room The I...

Страница 8: ...s used the amplifier is an integral part It supplies power to the IR receiver and any Outreach points as well as providing audio inputs and controls please refer to IAPA section for details on connect...

Страница 9: ...eiver Both inputs have their own level controls An additional line level output 18v DC supply and external low impedance speaker output are also features of this unit The unit is fitted with High and...

Страница 10: ...20 receiver only These terminals will provide a combined maximum output current of 500mA Line Output Balanced line level output terminals available on the IAPA for connection to the line level input o...

Страница 11: ...V GND SPARE A OUT A OUT 18v 0v 18v 0v Optional NO MORE THAN 5 OUTREACH PLATES SHOULD BE CONNECTED MIC OUTPUTS OUTPUT LEVEL SET AT MIC SENSOR INPUTS DC IN IR RECEIVER 1 4 JACK POWER CONNECTOR R O S N E...

Страница 12: ...w impedance Important note the speakers need to be wired in series parallel see diagram 4 Damage to the amplifierwilloccurifspeakerswithatotalimpedanceof less than 4 ohms are connected to these termin...

Страница 13: ...cult to remove and avoids accidental disconnection of power Note If the mains cable needs to be disconnected from the IRX unit break the clear plastic cover on the red button of the rear of the IEC pl...

Страница 14: ...vel signal from a music source such as a CD MP3 or laptop Set the volume control on the plate to maximum then adjust the line input on the Sound Panel amplifier or IRX to produce a reasonable level ov...

Страница 15: ...ernatively adjust the level of the amplifier unit installed to compensate The microphone may be muted at at any time by pressing the mute button on the transmitter front if muted this will illuminate...

Страница 16: ...t information Your IWM 402 is supplied with a set of rechargeable batteries However if these should become lost or require replacement it is critical that the following procedure is followed to allow...

Страница 17: ...ive on Waste Electrical and Electronic Equipment 2002 96 EC the WEEE Directive For disposal details please go on line to www iceilings uk com weee htm 17 www soundfield uk com For further details on t...

Страница 18: ...s However a number of acoustic factors lively noisy classes reverberant room conditions ambient noise from equipment outside hearing difficulties etc can have a significant effect on clear effective t...

Отзывы: