SL-2
User Guide
4
Attaching the SL-2
Power down the mixer-recorder and remove all power sources.
Proper and complete assembly of the SL-2 is required for optimal RF
emission performance. After removing the SL-2, it is important that
you replace all original screws on the 8-Series mixer-recorder.
See assembly instructions for the 8-Series model for which you will be
attaching the SL-2.
833 & 888
The following instructions describe attaching the SL-2 to the 833 and
888. For this assembly you will need:
•
833 or 888 Mixer-Recorder (not included)
•
SL-2
•
2x Rear Keyhole Pegs
•
2 mm Allen Wrench Hex 2-1/16”L
•
#4 Phillips Screwdriver (not included)
STEP 1
Remove the magnetic expansion port cover
on the top of the 833/888 by prying up gently to break
the magnetic connection. Attach the connector cover
to the bottom of the 833/888 for safekeeping.
STEP 2
Using a #4 Phillips Screwdriver, remove the two black
phillips screws from the Scorpio top panel as shown in the
image below. Keep these screws in a safe place as they need
to be re-installed if the SL-2 is removed from the 833/888.
STEP 3
Using the provided 2 mm Allen Wrench,
screw in two Rear Keyhole Pegs into the threads
where you removed the screws in Step 2.
STEP 4
Align the SL-2’s bottom panel hooks with the Rear Keyhole
Pegs on the 833/888. The SL-2 should be tilted with the front
panel slightly higher than the rear. Take care not to bump the SL-2
expansion connector against the 833/888 top panel. Once the
SL-2’s Bottom Panel hooks and Rear Keyhole Peg’s machined
grooves are aligned, slide the SL-2 towards the front panel.
On an 833, the back of the silver mount screws will rest against this
indent.
On an 888, the silver mount screws will fit inside this hole.