15
When the “ ” indicator light on the control panel flashes, the Electronic cell needs to be cleaned.
Cleaning the electronic cell
Remove the electronic cell
1. Stop the operation and unplug the unit. Take off the back panel.
2. Hold the Electronic cell’s handle, pull it toward to you.
Cleaning the electronic cell
1. Use a large enough container, such as a laundry tub or trash container.
Dissolve detergent in warm water to cover the cell. After the detergent
has completely dissolved, place the cell in the container. Allow the cell
to soak for 15~30 minutes and rinse with clean water.
2. Dry the cell thoroughly with heat gun before reinstalling.
3. After cleaning the Electronic cell, hold the “ ” button 3 seconds or
press the reset button on the remote control to reset the time for the cell.
Warning
If the air quality is extremely poor and the cell is dirty, you may clean the cell before the indicator light flashes.
DO NOT clean the cell with alcohol, gasoline, paint thinner or other flammable substances. It may cause fire!
Before Remove the electronic cell, stop the operation and unplug the unit.
DO NOT reinstall the cell until it is completely dry. If the“ ” indicator light on the control panel flashes,
then the cell may still be wet.
Be careful not to snag or cut the ionizing wire. If the unit is operated with the ionizing wire cut, there will be
no dust collection.
E
E
Care and Maintenance 2