Страница 1: ...Operation Manual SOTO G5 MEDICAL AIR PURIFIER Before operating the system please read this manual thoroughly and retain it for future reference Top Grade Air Purifier ...
Страница 2: ...This is Soto If you have the opportunity to experience SOTO air purifiers please remember that they are designed with our dreams to meet your expectations ...
Страница 3: ...5 06 07 08 09 10 13 14 17 18 19 Consumer Limited Warranty Safety Precautions How it Works Features and Specifications Part Name Installation Operation Care and Maintenance Troubleshooting Filter Maintenance Schedule ...
Страница 4: ...ubject to normal wear unless they are defective in material or workmanship 1 Any defects caused or repairs required because of abusive operation negligence accident improper installation or inappropriate use as outlined in the operation manual 2 Any product tampered with modified adjusted or repaired by any party other than SOTO 3 Damaged caused or repairs because of the use with items not specifi...
Страница 5: ... pull by the cord Do not handle plug or appliance with wet hands Electrical shock or fire from short circuit may occur To avoid causing fire do not attempt to disassemble the unit only certified technicians should do this Stop the unit and unplug the power when maintenance Do not insert fingers or foreign objects into the intake or air outlet Keep hair loose clothing fingers and all parts of body ...
Страница 6: ...urifier functions as an air cleaner by helping to disinfect airborne microorganisms and removing particulates from the air The DC fan of the unit draw air through the bottom Intake of the unit Then it passes through the Pre filter UV lamp Photo catalytic filter Electronic cell Electrostatic adsorption device HEPA filter and Activated carbon filter The purified air is then released through the outl...
Страница 7: ... 250V 3A 48cm x 48cm x H136 5cm 53kg 1 The odor and particle sensor can let the unit automatically select the appropriate fan speed depending on the air quality detected 2 The G5 can be operated completely with the wave of your hand making it suitable in medical settings to avoid cross contamination 3 The indicator lights tell you when to replace the Pre filter HEPA filter and the Activated carbon...
Страница 8: ... Panel 03 Back Panel 04 Fan motor 05 Main Circuit Board 06 UV Ballast 07 LED Display Board 08 Ion Generator 09 PC Display Panel 10 Pre filter 11 Photo Catalytic Filter 12 UV Lamp 13 Electronic Cell 14 HEPA Filter 15 Activate Carbon Filter 16 Power supply 17 Handle 18 Back Panel Key 19 Castors ...
Страница 9: ...han 90 for indoor air Applicable places and Operation 1 Before operating the unit open the back panel and take out the pre filter HEPA filter and Carbon filter then remove plastic packaging from all the filters 2 Plug the power cord of the unit into a nearby power outlet 3 The unit has a remote control Put the batteries into the remote control before using it Before operation 1 Power supply condit...
Страница 10: ...te changes as shown below L M H AUTO 3 TIMER Button Press this button to select the time for operation The timer setting switches as shown 1 2 4 C timer cycle function cancel timing 4 NEG ION Button Turns Negative Ions on and off 5 UV LAMP Button When the button is pressed it will turn off the UV lamps pressing again will turn on the UV light 6 NIGHT Button When pressed all the indicator lights on...
Страница 11: ... clock time when the unit has no time set When the scheduled operation time is set the OFF indicator will light up under the running state and display the shutdown time When in the power off state the ON indicator will light up and display the power on time 5 PM2 5 display Real time display the indoor PM2 5 concentration μg m 6 Indoor TVOC pollution level display 7 Indoor Temperature display 8 Ind...
Страница 12: ... the Carbon filter needs to be replaced 13 Pollutant level display See the chart The different colors indicate the air quality Blue Good Orange Unhealthy Red Hazardous Use your hand to wave over the sensor this waving motion turns the unit on off and can also adjust the fan speed Hover hold your hand over the sensor for 2 seconds and this will lock the unit at the desired speed This will prevent a...
Страница 13: ...me of the unit through the same time setting method c Press the TIME button a third time the OFF indicator light on the display panel is light on At this point according to the same time setting method press the or buttons to set the unit s shutdown time d Press the button to confirm the above time setting At this time the unit is turned on and off at the set time every day 3 SPEED Button The fan ...
Страница 14: ... replaced when the indicator lights are flashing When maintenance on the unit be sure to unplug the power cord and never handle the plug with wet hands If so electrical shock and bodily injury may occur as a result Replacing the pre filter Main unit 1 Stop the operation and unplug the unit 2 Rotate the door lock and pull the back panel toward to you then take off the back panel 3 Gently pull out t...
Страница 15: ...l thoroughly with heat gun before reinstalling 3 After cleaning the Electronic cell hold the button 3 seconds or press the reset button on the remote control to reset the time for the cell Warning If the air quality is extremely poor and the cell is dirty you may clean the cell before the indicator light flashes DO NOT clean the cell with alcohol gasoline paint thinner or other flammable substance...
Страница 16: ...t the Activated carbon filter Replacing the HEPA filter and the Carbon filter Warning DO NOT reuse or clean the Pre filter HEPA filter and the carbon filter DO NOT clean the Pre filter HEPA filter and the carbon filter with liquid especially alcohol gasoline paint thinner etc It may cause fire Remove plastic packaging from the Pre filter HEPA filter and the carbon filter before operation After rep...
Страница 17: ...nds to reset the time for the UV lamps Replacing UV Lamps Photo catalytic filter Photo catalytic filter is permanent never needs replacing When there is dust on it clean the dust off using a vacuum cleaner dusting brush Donot wash it in water Never look directly at UV lamps Direct exposure to germicidal light can cause temporary or chronic damage to your eyesight or even blindness Always unplug th...
Страница 18: ... back panel properly and check the interlock switch The cell may be wet after cleaning Dry it thoroughly If not call the customer service The unit does not operate When functions do not work properly Wash it and dry completely before reinstalling it Replace the pre filter HEPA filter or the carbon filter Get rid of foreign materials around the inlet or outlet Service problems that appear to be maj...
Страница 19: ...Filter Maintenance Schedule 19 Pre filter Replace Reminder Electronic Cell Wash Reminder Year J F M A M J J A S O N D Year J F M A M J J A S O N D ...