Soshine 12.8V24AH Скачать руководство пользователя страница 2

DOC: 

IFR12.8V24AH(4S4P)M5       

                                     

Page 

2

 Of 

Pages

1

 

Model: IFR12.8V24AH(4S4P)M5

 

2

 

Application Condition

 

Customers should use the battery according to the following correct conditions of use, customer should apply BMS to monitor, 
manage and protect each battery.

 

 

2.1

   Authorization

 

Without authorization, the customer shall not modify or change the design and framework of the battery management system, to 
make sure not to affect the performance of the battery.

 

 

2.2

   Management files

 

Customer  shall  build  the  battery  management  files.  The  customer  shall  keep  the  monitoring  data  of  the  complete  battery 
operation as a reference for product quality responsibility. 

 

The Soshine does not undertake the product quality assurance responsibility without the inspection data of the complete battery 
system.

 

 

2.3

   Management system requirements

 

The battery management system needs to meet the following basic requirements:

 

No.

 

Parameter

 

Specification

 

Protection Action

 

2.3.1

 

Absolute Charge

 

14.2V

 

Stop charging when the voltage reaches 14.2V

 

2.3.2

 

Absolute Discharge

 

10.8V (Min.)

 

Stop discharging when the battery voltage reaches 10.8V, 
Minimize the current

 

2.3.3

 

Charge mode 

 

CC/CV

 

Constant  current  charging  to  14.2V,  constant  voltage  charging 

to 14.2V. Cutoff current 0.01C(240mA)

 

 

 

2.3.4

 

Short-circuit Protection

 

Disconnect

 

When a short circuit occurs, the battery is disconnected from the 
over current

 

2.3.5

 

Over current Protection

 

According to 4.11, and 

4.14

 

the battery management system controls the discharge current 
to meet the specifications

 

2.3.6

 

Overheat Protection

 

According to4.16 and 

4.17

 

The charge/discharge is terminated when the temperature 
exceeds the specification of this specification

 

2.3.7

 

Charging Time Protection

 

Within 8 hours

 

Stop charging when charging time is over 8 hours

 

NOTES: As for above No. 11.3.1, 11.3.2, 11.3.4, 11.3.6 are warning clauses, the customer please note: when the battery 

reaches any of these describe indicators and parameters, it means that the battery has already beyond the conditions of use, the 

customer should be in accordance with the "protection" and other relevant provisions this specification of battery protection 

measures, at the same time, Soshine statement on the using state of the battery does not undertake any guarantee responsibility 

for the quality.

 

 

2.4 

  Charge

 

Charging current: The maximum charging current specified in the specification cannot be exceeded.

 

Charging voltage: Not exceed the highest limit voltage specified in the specification.

 

Charging temperature: The charging temperature of the battery must be performed in accordance with the temperature range of 
the specification.

 

Charging method: Constant current and then constant voltage charging.

 

 

 

Содержание 12.8V24AH

Страница 1: ...DOC IFR12 8V24AH 4S4P M5 Page 1 Of 9 Pages LiFePO4 Battery 12 8V24AH Instruction Manual Soshine International www soshine com cn summer soshine com cn...

Страница 2: ...01C 240mA 2 3 4 Short circuit Protection Disconnect When a short circuit occurs the battery is disconnected from the over current 2 3 5 Over current Protection According to 4 11 and 4 14 the battery...

Страница 3: ...quality assurance 2 9 Battery heat diffusion In the design of the electric box the heat diffusion of the battery should be fully considered Soshine shall not be responsible for the quality assurance...

Страница 4: ...5C 12A For continuous discharge mode Ambient temperature 25 C 4 14 Discharge Current 2C Maximum 24A The surface temperature of the cells 60 C 4 15 Impedance Battery Internal 60m Internal resistance me...

Страница 5: ...rotection Overcharge protection delay 0 5S 2S 5 8 Protective voltage 2 0 0 1V 5 9 Restore voltage 2 70 0 1V 5 10 Over discharge protection delay 10 200mS 5 11 Over discharge protection Over current pr...

Страница 6: ...s essentially flat meaning that a 20 charged battery will be providing nearly the same output voltage as an 80 charged battery This prevents any issues caused by the voltage sag common to lead acid as...

Страница 7: ...FR12 8V24AH 4S4P M5 Page 7 Of 9 Pages 8 Battery Initial Dimensions and Label 8 1 Dimensions 8 2 Battery label No Item Unit mm 1 Battery length L 181 0 2 2 Battery width W 167 0 2 3 Battery height H 77...

Страница 8: ...hould stop using the battery Any violation of the requirements shall be exempted from Soshine s quality guarantee responsibility which based on product sales contract and this specification 11 Storage...

Страница 9: ...s specification shall be agreed by both parties 16 CAUTIONS IN USE To ensure proper use of the battery please read the manual carefully before using it Handling When charging and discharging do not re...