SOR 1267AFR-1 Скачать руководство пользователя страница 1

Form 1630 (09.18) ©SOR Inc. 

1/8

The 1267 Air Filter Regulator is designed for air or 
gas service. Maximum allowable inlet pressure is 
250 psi (17 bar). Operating temperatures are 0°F 
to 160°F (-18°C to 71°C). The 1267AFR has low 
capacity internal relief which provides very limited 
downstream overpressure protection.

1267AFR

Air Filter Regulator

  General Instructions

Registered Quality System to ISO 9001

Design and 

specifications are 

subject to change 

without notice. 

For latest revision, go to 

sorinc.com

NOTE: If you suspect that a product is defective, contact the factory or the SOR

®

 Representative 

in your area for a return material authorization number (RMA). This product should only be 
installed by trained and competent personnel.

Table of Contents

Installation .......................................2
Calibration .......................................2
Maintenance .....................................3
Specifi cations ...................................4
Materials .........................................4 
Parts List .........................................5
Dimensions ................................... 6-7

The internal relief valve in the 1267AFR does 
not provide full overpressure protection and 
is designed for minor seat leakage only. To 
avoid exceeding outlet pressure limits in 
service, a pressure-relieving or pressure-
limiting device should be provided. Leakage, 
equipment damage, or personal injury can 
result from over-pressuring the regulator.

All SOR instructions, as well as applicable local, state, and federal codes 
and regulations should be adhered to when performing installation, 
operation, or maintenance of a regulator. Personal injury, equipment 
damage, or leakage can occur if the regulator is over-pressured or physically 
damaged. To avoid physical damage the regulator should be installed in a 
safe location. The regulator shouldn’t be installed in systems that exceed 
the specifi ed pressure limit of 250 psi (17 bar). If leakage develops, then 
maintenance is required. Failure to remove the regulator from service 
immediately may create a hazardous situation.

T bl

f C

t

t

es 

e, 

Содержание 1267AFR-1

Страница 1: ...4 Parts List 5 Dimensions 6 7 The internal relief valve in the 1267AFR does not provide full overpressure protection and is designed for minor seat leakage only To avoid exceeding outlet pressure lim...

Страница 2: ...otating the bonnet relative to the body may change the vent hole orientation Exhaust may be remotely vented by installing tubing to the NPT port E Accessory Tapped Exhaust The 1267AFR may vent some ga...

Страница 3: ...of the unit and remove the drip well housing Remove the filter retaining screw Remove the pintle spring the pintle and pintle spring will be accessible upon removal of the base Clean the parts as need...

Страница 4: ...unting Pipe Bracket or Direct through body mounting holes Filter 40 micron F Accessory 5 micron Exhaust Capacity 0 1 scfm 3 Nl min with downstream pressure 5 psig 0 3 bar above setpoint Sensitivity 1...

Страница 5: ...7 1 Body 11 1 Base Assembly 12 4 10 24 Dripwell Screw 14 1 Filter Retainer 15 1 Dripwell 16 1 Drain Valve Parts List 1267AFR 2 1 2 NPT Item Qty Description 7 1 Body 9 1 Valve Spring 11 1 Base Assembly...

Страница 6: ...mm D in mm E in mm F in mm G in mm 1 4 2 66 67 6 1 0 25 4 3 42 86 8 7 15 181 6 2 25 57 2 3 19 81 0 1 22 31 0 Dimensions shown are for reference only Linear in mm DRAIN VALVE ADJUST SCREW ASSEMBLY BONN...

Страница 7: ...VE BODY ASSEMBLY DRIPWELL HOUSING RANGE SPRING SPRING GUIDE ADJUST SCREW ASSEMBLY BONNET DIAPHRAGM ASSEMBLY FILTER Port Size NPT A in mm B in mm C in mm D in mm E in mm F in mm G in mm 1 2 2 83 71 9 1...

Страница 8: ...8 8 Form 1630 09 18 SOR Inc 14685West105thStreet Lenexa KS66215 913 888 2630 800 676 6794USA Fax913 888 0767 Registered Quality System to ISO 9001 Printed in USA sorinc com...

Отзывы: