Sophos XGS 4300 Скачать руководство пользователя страница 11

11

XGS 4300/4500

Operating Instructions

Rack Mounting Considerations

 

Ì

Ambient operating temperature:

 If installed in a closed or multi-unit rack assembly, 

the ambient operating temperature of the rack environment may be greater than the 
ambient temperature of the room. Therefore, you should install the equipment in an 
environment compatible with the manufacturer’s maximum rated ambient temperature.

 

Ì

Reduced airflow:

 Equipment should be mounted into a 

rack with sufficient airflow to allow cooling.

 

Ì

Mechanical loading:

 Equipment should be mounted into a rack so that a 

hazardous condition does not arise due to uneven mechanical loading.

 

Ì

Circuit overloading:

 Consideration should be given to the connection of the equipment 

to the power supply circuitry and the effect that any possible overloading of circuits 
might have on overcurrent protection and power supply wiring. Appropriate consideration 
of equipment nameplate ratings should be used when addressing this concern.

 

Ì

Reliable ground:

 Reliable grounding must be maintained at all times. To ensure 

this, the rack itself should be grounded. Grounding screws for the appliance 
are on the rear of the chassis.  Chassis Grounding is required. Particular 
attention should be given to power supply connections other than the direct 
connections to the branch circuit (i.e., the use of power strips, etc.).

Rack Mounting Instructions

To mount the appliance to the rack you need the delivered rack-mount kits. There are a 
variety of rack units on the market, which may mean the assembly procedure will differ 
slightly. You should also refer to the installation instructions that came with the rack unit 
you are using. Please observe the mounting instructions for your rack.

Important note:

 Make sure you use the screws supplied with the rack-mount brackets. 

Using the wrong screws could damage the hardware appliance and would invalidate your 
warranty.

1. 

Attach the rack-mount ears to the appliance:

 

Ì

Place the appliance on a hard flat surface with the front panel facing you.

Please Note:

 There are two types of mounting brackets supplied with your appliance. Use 

the short brackets if you intend to also use sliding rails which are available as an optional 
accessory from your Sophos partner. Use the long mounting brackets if you don’t want to 
use additional sliding rails or any other fixation for the appliance.

 

Ì

Attach the rack–mount brackets to the left and right side 
of the appliance with the supplied screws.

 

Ì

Make sure the brackets are properly attached to the appliance.

Содержание XGS 4300

Страница 1: ...Operating Instructions XGS 4300 4500...

Страница 2: ...bols The following symbol and its meaning appears in the Hardware Quick Start Guide Safety Instructions and in these Operating Instructions Caution and Important Note If these notes are not correctly...

Страница 3: ...S 4300 4500 Multi function LCD display and navigation 2 x expansion bay shown with optional modules LAN 1 4 4 x GbE copper 2 bypass pairs ports 1 2 and 3 4 F1 F4 4 x SFP fiber ports LAN 5 8 4 x 2 5 Gb...

Страница 4: ...ection settings are Bits per second 38 400 Data bits 8 Parity N none Stop bits 1 USB USB 3 0 Type A You can connect a USB 2 0 or 3 0 compatible device to this port e g USB thumb drive UPS 3G 4G dongle...

Страница 5: ...52 W 519 BTU hr 152 W 519 BTU hr Mounting Rackmount 1U sliding rails option min rack depth 603 mm 23 74 max rack depth 930 mm 36 61 Rackmount 1U sliding rails option min rack depth 603 mm 23 74 max ra...

Страница 6: ...ating at 1000 Mbps Off If Ethernet port is operating at 100 Mbps LEDs on each SFP connector ACT LNK Green Solid 1 The SFP connector is receiving power 2 Good connection between the SFP port and hub Fl...

Страница 7: ...0 Main Menu 2 Network Menu Network Menu 1 Show Port A1 LAN Port A1 LAN 172 16 16 16 Network Menu 2 Show Port A2 WAN Port A2 WAN IP NOT ASSIGN Network Menu 3 Show Port A3 NA Port A3 NA IP NOT ASSIGN N...

Страница 8: ...ill shut down the system completely and reboot Control Key Functions The current menu is left When the key is pressed a couple of times the modifications are discarded and the initial state will be di...

Страница 9: ...key to continue 8 Factory Reset 1 Confirm Asks for Confirmation 9 ENTER Shutdown Complete Reboot Machine S NO Action Item press What you see on the LCD What it means 1 SOPHOS Protection Appliance is...

Страница 10: ...eight of the rack resting on them In single rack installation stabilizers should be attached to the rack In multiple rack installations the racks should be coupled together Always make sure the rack i...

Страница 11: ...sis Chassis Grounding is required Particular attention should be given to power supply connections other than the direct connections to the branch circuit i e the use of power strips etc Rack Mounting...

Страница 12: ...min Quick Start Guide or cancel it and perform a manual setup see the Sophos Firewall How To Library SFP SFP Ports The XGS 4300 4500 models offer a variety of SFP SFP ports allowing you to plugin vari...

Страница 13: ...e connected then the micro USB port will take precedence You can use for instance the Hyperterminal terminal program which is included with most versions of Microsoft Windows to log on to the applianc...

Страница 14: ...9409 9100 Email sales sophos com au Asia Sales Tel 65 62244168 Email salesasia sophos com Copyright 2021 Sophos Ltd All rights reserved Registered in England and Wales No 2096520 The Pentagon Abingdon...

Отзывы: