3
XC-ST70/70CE
MAIN SPECIFICATIONS
Image pickup device: 2/3-inch interline transfer CCD
Number of effective pixels
XC-ST70:
768(H)
x
494(V)
XC-ST70CE:
752(H)
x
582(V)
CCD horizontal driving frequency
XC-ST70:
14.318 MHz
XC-ST70CE:
14.187 MHz
CCD vertical driving frequency
XC-ST70:
15.734 kHz
XC-ST70CE:
15.625 kHz
Signal system
EIA/CCIR
Cell size
XC-ST70:
11.6(H)
x
13.5(V) um
XC-ST70CE:
11.6(H)
x
11.2(V) um
Lens mount
C-mount
Flange back
17.526 mm
Synchronization system
Internal/external
(Selected automatically.)
External sync input/output
HD/VD (2 to 5 Vp-p)
VS (Sync level: 0.3 Vp-p
+0.3 V
)
–0.15 V
*
Automatically selected according
to the existence of an input signal
when the selection switch on the
rear panel is set to EXT.
Allowable frequency deviation of external synchronization
±
1 %
(in horizontal synchronous frequency)
Jitter
Within
±
50 nsec
Scanning system
2:1 interlacing
Non-interlacing
(during external sync input)
Horizontal resolution
XC-ST70:
570 TV lines
XC-ST70CE:
560 TV lines
Sensitivity
400 lx F8 (
γ
= ON, 0 dB)
S/N ratio
XC-ST70:
60 dB
XC-ST70CE:
58 dB
Minimum subject illuminance
0.3 lx (F1.4, AGC ON)
Gain
AGC/Manual/Fixed
(Can be selected using the switch
on the rear panel.)
Gamma correction
ON/OFF
(Can be selected using the switch
on the rear panel.)
Electronic shutter
XC-ST70:
1/100 to 1/10,000 seconds
XC-ST70CE:
1/120 to 1/10,000 seconds
External trigger shutter
XC-ST70:
1/4 to 1/10,000 seconds
XC-ST70CE:
1/4 to 1/8,000 seconds
*
Set using the DIP switch on the rear panel, or
continuously variable with the trigger pulse
width.
Supply voltage
+12 VDC (
±
10%)
Power consumption
2.1 W
Operating temperature –5 ˚C to +45 ˚C
Storage temperature –30 ˚C to +60 ˚C
Performance assurance temperature
0 ˚C to +40 ˚C
Operating humidity
20 to 80 % (Non-condensing)
Storage humidity
20 to 95 % (Non-condensing)
Vibration resistance
10G
(For 20 minutes in the X, Y, and Z
directions at 20 to 200 Hz)
Shock resistance
70G
Outside dimensions
44(W)
x
29(H)
x
57.5(D) mm
Weight
105 g
Standards
UL1492, FCC Class A Digital
Device, and CE (EN50081-2 +
EN50082-2)
Other
Restart Reset function frame or
field integration can be selected.
Conforms to new 12-pin EIAJ.
Accessories
Lens mount cap (1)
Instruction Manual (1)
External synchronization for each mode
Mode
Normal
Normal shutter
Restart Reset
Mode 1
non-reset
External trigger shutter
Mode 2
reset
Trigger signal
generates an
internal VD
(single) signal.
Internal sync
External sync
HD/VD
×
: Can be used.
×
: Cannot be used.
VS
×
×
×
×