– 8 –
FM SECTION
Setting:
FM/AM/TAPE (RADIO OFF) switch: FM
Repeat the procedure in each adjustment several times since L (3,
2) affects CT1 (3, 2) and CT1 (3, 2) affects L (3, 2). Both the
frequency coverage and tracking adjustments should end with the
final adjustment of the trimmer capacitors.
FM Frequency Coverage Adjustment
((
)): Italian, Saudi Arabia model, [
]: East European model
FM Tracking Adjustment
((
)): Italian, Saudi Arabia model, [
]: East European model
0 dB=1
µ
V
TUNER SECTION
FM RF Signal
generator
0.01
µ
F
MAIN board
(FM RF-IN)
(GND)
75 kHz frequency
deviation by 1 kHz signal
Output level: as low possible.
Pointer
SG
Adjustment
Reading on
position
frequency
part
level meter
86 MHz
f minimum
((87.35 MHz))
L3
[64 MHz]
maximum
109.5 MHz
f maximum
((108.25 MHz))
CT1-3
[109.5 MHz]
SG and set
Adjustment
Reading on
frequency
part
level meter
86 MHz
((87.35 MHz))
L2
[64 MHz]
maximum
109.5 MHz
((108.25 MHz))
CT1-2
[109.5 MHz]
AM SECTION
Setting:
FM/AM/TAPE (RADIO OFF) switch: AM
Repeat the procedure in each adjustment several times since L (4,
1) affects CT1 (4, 1) and CT1 (4, 1) affects L (4, 1). Both the
frequency coverage and tracking adjustments should end with the
final adjustment of the trimmer capacitors.
AM IF Adjustment
AM Frequency Coverage Adjustment
(
): AEP, E model, ((
)): Italian, Saudi Arabia model,
[
]: East European model
AM Tracking Adjustment
((
)): Italian, Saudi Arabia model,
[
]: East European model
AM RF Signal
generator
Put the lead-wire
antenna close to
the set.
30% amplitude modulation by
400 Hz signal
Output level: as low possible.
SG and set
Adjustment
Reading on
frequency
part
level meter
1,000 kHz
T1
maximum
Pointer
SG
Adjustment
Reading on
position
frequency
part
level meter
505 kHz
f minimum
(505 kHz)
L4
((516.5 kHz))
[505 kHz]
maximum
1,750 kHz
f maximum
(1,680 kHz)
CT1-4
((1,631.5 kHz))
[1,680 kHz]
SG and set
Adjustment
Reading on
frequency
part
level meter
620 kHz
((800 kHz))
L1
[620 kHz]
maximum
1,400 kHz
((1,300 kHz))
CT1-1
[1,400 kHz]
i
jack
FX373 (Canadian): 32
Ω
others: 16
Ω
set
+
level meter
–
i
jack
FX373 (Canadian): 32
Ω
others: 16
Ω
set
+
level meter
–