— 17 —
KV-21ME43
KV-21ME43
KV-21ME43
KV-21ME43
KV-21ME43
SECTION 4
SECTION 4
SECTION 4
SECTION 4
SECTION 4
SAFETY
SAFETY
SAFETY
SAFETY
SAFETY RELA
RELA
RELA
RELA
RELATED
TED
TED
TED
TED ADJUSTMENTS
ADJUSTMENTS
ADJUSTMENTS
ADJUSTMENTS
ADJUSTMENTS
4-1.
4-1.
4-1.
4-1.
4-1.
R582 CONFIRMA
R582 CONFIRMA
R582 CONFIRMA
R582 CONFIRMA
R582 CONFIRMATION METHOD
TION METHOD
TION METHOD
TION METHOD
TION METHOD
(HV HOLD-DOWN CONFIRMA
(HV HOLD-DOWN CONFIRMA
(HV HOLD-DOWN CONFIRMA
(HV HOLD-DOWN CONFIRMA
(HV HOLD-DOWN CONFIRMATION)
TION)
TION)
TION)
TION)
AND READJUSTMENTS
AND READJUSTMENTS
AND READJUSTMENTS
AND READJUSTMENTS
AND READJUSTMENTS
The following adjustments should always be performed when
replacing the following components which are marked with
on the schematic diagram.
DY
DY
DY
DY
DY, C51
, C51
, C51
, C51
, C511, C574, C575, D572, D573, D574, R578,
1, C574, C575, D572, D573, D574, R578,
1, C574, C575, D572, D573, D574, R578,
1, C574, C575, D572, D573, D574, R578,
1, C574, C575, D572, D573, D574, R578,
R582, R583, R584, R585, R586, R625, R626, R635,
R582, R583, R584, R585, R586, R625, R626, R635,
R582, R583, R584, R585, R586, R625, R626, R635,
R582, R583, R584, R585, R586, R625, R626, R635,
R582, R583, R584, R585, R586, R625, R626, R635,
R640, T504, IC301, IC521, IC602
R640, T504, IC301, IC521, IC602
R640, T504, IC301, IC521, IC602
R640, T504, IC301, IC521, IC602
R640, T504, IC301, IC521, IC602
Preparation Before Confirmation
Preparation Before Confirmation
Preparation Before Confirmation
Preparation Before Confirmation
Preparation Before Confirmation
1. Turn the POWER switch ON. Input an entirely white
signal and set the PICTURE and BRIGHTNESS controls
to maximum.
2. Confirm that the voltage between C574 (+) and ground
is more than 99.8 VDC when the set is operating normally
with 120-220±VAC.
Hold-down Operation Confirmation
Hold-down Operation Confirmation
Hold-down Operation Confirmation
Hold-down Operation Confirmation
Hold-down Operation Confirmation
1. Connect the current meter between Pin 11 of the FBT
(T504) and the PCB land where Pin 11 would normally
attach. (See Figure 1 on the following page.)
2. Input a dot signal and set PICTURE and BRIGHTNESS
to minimum: IABL = 95 + 100/-95
µ
A.
3. Confirm the voltage of A Board TP-600 is
117.0 ± 0.3 VDC.
4. Connect the digital voltmeter and the DC power supply
via diode 1SS119 to C574 (+) and ground
(See Figure 1 on the following page).
5. Increase the DC power voltage gradually until the picture
blanks out.
6. Read the digital voltmeter indication.
7. Turn DC power source off immediately:
(standard: less than or equal to 127.3 VDC).
8. Input a white signal and set PICTURE and BRIGHTNESS
to maximum: (standard: less than or equal to 127.3 VDC).
9. Repeat steps 4 to 7.
Hold-down Readjustment
Hold-down Readjustment
Hold-down Readjustment
Hold-down Readjustment
Hold-down Readjustment
If the setting indicated in step 2 of Hold-down Operation
Confirmation cannot be met, readjustment should be performed
by altering the resistance value of R582, a component marked
with
.
+
I ABL
ABL
T504
FBT
Range
-
Ammeter
3.0 mA DC
A
4-2.
4-2.
4-2.
4-2.
4-2. B+ VOL
B+ VOL
B+ VOL
B+ VOL
B+ VOLT
T
T
T
TAGE CONFIRMA
AGE CONFIRMA
AGE CONFIRMA
AGE CONFIRMA
AGE CONFIRMATION
TION
TION
TION
TION AND
AND
AND
AND
AND
ADJUSTMENT
ADJUSTMENT
ADJUSTMENT
ADJUSTMENT
ADJUSTMENT
Note: The following adjustments should always be performed
when replacing the following components, which are marked
with on the schematic diagram.
IC001, IC602, R030, R625, R626, R632, R633, R635,
IC001, IC602, R030, R625, R626, R632, R633, R635,
IC001, IC602, R030, R625, R626, R632, R633, R635,
IC001, IC602, R030, R625, R626, R632, R633, R635,
IC001, IC602, R030, R625, R626, R632, R633, R635,
R636, R637, R638, R639
R636, R637, R638, R639
R636, R637, R638, R639
R636, R637, R638, R639
R636, R637, R638, R639
1. Supply 120-220±VAC to the set with a variable auto
transformer.
2. Input a dot signal.
3. Set the PICTURE and BRIGHTNESS controls to minimum.
4. Set to Service Adjustment Mode.
5. Select PADJ with
and
.
6. Adjust with
to the 0 level.
7. Confirm the voltage of A board TP-600 is less than
125 VDC.
8. If step 7 is not satisifed, replace the components and repeat
the above steps.
9. Supply 120-220±VAC to the set with a variable auto
transformer.
10. Adjust with
and
for 117.0 ± .3 VDC.
11. Press
then
to save into the memory.
Содержание TRINITRON RM-Y156
Страница 24: ... 24 KV 21ME43 KV 21ME43 KV 21ME43 KV 21ME43 KV 21ME43 NOTES ...
Страница 25: ... 25 KV 21ME43 KV 21ME43 KV 21ME43 KV 21ME43 KV 21ME43 NOTES ...
Страница 26: ... 26 KV 21ME43 KV 21ME43 KV 21ME43 KV 21ME43 KV 21ME43 NOTES ...
Страница 38: ... 86 NOTES NOTES 50 KV 21ME43 KV 21ME43 KV 21ME43 KV 21ME43 KV 21ME43 ...