![Sony Trinitron KV-XF34M97 Скачать руководство пользователя страница 36](http://html.mh-extra.com/html/sony/trinitron-kv-xf34m97/trinitron-kv-xf34m97_service-manual_1330371036.webp)
http://cxema.ru
– 36 –
KV-XF34M97
RM-953
2. WHITE BALANCE ADJUSTMENT
1) Set to Service Mode (Refer Section 4-1: ADJUSTMENTS
WITH COMMANDER).
2) Input white raster signal.
3) Set the PICTURE to minimum.
4) Select GCT (WHB 4) and BCT (WHB 5) with
[1]
and
[4]
, and
adjust the level with
[3]
and
[6]
for the best white balance.
5) Set the PICTURE to maximum.
6) Select GDR (WHB 1) and BDR (WHB 2) with
[1]
and
[4]
, and
adjust the level with
[3]
and
[6]
for the best white balance.
7) Write into the memory by pressing
[MUTING]
then
[0]
.
3. SUB BRIGHT ADJUSTMENT
1) Set to service mode.
2) Input a staircase signal of black to white from the pattern
generator.
3) BRIGHTNESS .... 50%.
PICTURE ............ MINIMUM
4) Select SBR (WHB7) with
[1]
and
[4]
, and adjust SBR (WHB7)
level with
[3]
and
[6]
so that the second stripe from the right is
dimly lit.
3-4. G2 (SCREEN) AND WHITE BALANCE
ADJUSTMENTS
1. G2 (SCREEN) ADJUSTMENT
1) Set the PICTURE and BRIGHTNESS to normal.
2) Put to VIDEO mode without signals.
3) Connect R, G and B of the C board cathode to the oscilloscope.
4) Adjust BRIGHTNESS to obtain the cathode voltage to the value
below.
5) Adjust G2 (screen) on the FBT until picture shows the point
before cut off.
White
second from the right
Black
0 V
Cathode setting voltage:
175 V
±
2 (VDC)…34”, 25”, 21”
180 V
±
2 (VDC)…29”
Содержание Trinitron KV-XF34M97
Страница 45: ...http cxema ru 45 KV XF34M97 RM 953 MEMO ...
Страница 46: ...http cxema ru 46 KV XF34M97 RM 953 MEMO ...
Страница 63: ...http cxema ru 93 VM1 Board PRINTED WIRING BOARD VM1 VELOCITY MODULATION ...
Страница 66: ...http cxema ru ...
Страница 67: ...http cxema ru ...
Страница 68: ...http cxema ru ...
Страница 69: ...http cxema ru ...