– 53 –
KV
-XF29M50/XF29M80/XF29K94
RM-954
RM-962
Adjustment Item Table
Device
Functionality
Note
Data Range
Function
Note for
Register
Slava
RAM Address
Name
No
Name
Different Data
No. (bit)
Address
(bit)
SVP
0
SBF
22
3F
SECAM BELL f0
1C (7-2)
CXA2060AS(8AH)
89 (7-2)
1
HOS
7
0F
H Oscillation
0C (7-4)
84 (7-4)
2
SHU
8
0F
Sub Hue Control
TV/Video
05 (7-2)
31E
3
SCL
1F
3F
Sub Color Control
NTSC/Others
04 (7-2)
31F
PIP
0
SDL
2
0F
Delay of output SELECT
01 (6-3)
SDA9288X(D6H)
190 (6-3)
1
PPH
15
FF
H Position of TOP-LEFT Pin P
01/02
19F
2
PPV
2E
FF
V Position of TOP-LEFT Pin P
03 (7-0)
1A0
3
YDL
0
07
Delay of Luminance Input
04 (2-0)
193 (2-0)
4
HDI
0
0F
H Sync Delay for Inset
06 (3-0)
195 (3-0)
5
ISC
1
1
Inset Clock Selection
06 (4)
195 (4)
6
CLP
1
1
Clamp Pulse Selection
06 (5)
195 (5)
7
CLC
0
1
Clamp Cycle Selection
06 (6)
195 (6)
8
CON
0
0F
Contrast Adjustment for inset
09 (7-4)
198 (7-4)
9
PLL
2
03
H Position For A-ch
0D (6-5)
19C (6-5)
10
PDV
0
0F
PIP V Pedestal Level
0E (7-4)
19D (7-4)
11
PDU
0
0F
PIP U Pedestal Level
0E (3-0)
19D (3-0)
TXT
0
TXH
1
3
Teletext Horizontal Position
10 (1-0)
SAA5261(58H)
357 (1-0)
1
TXV
0
3
Teletext Vertical Position
10 (5-4)
357 (5-4)
OPM
0
OSH
11
3F
OSD H Position
Option-Misc
1F1
CXP750097
17B (7-2)
1
COM
3
03
Comb Selection (00-No Comb, 01-Glass Comb,
34D (7-6)
02-Digital Comb, 03-Multi-Standard Comb)
2
APC
1
1
APC Switch
34C (5)
3
TSY
0
03
TV Sys at Auto TV Sys
34C (4-3)
4
MUT
1
1
No Signal Mute
34C (0)
5
AFM
1
1
Auto FM switch
34C (1)
6
RFB
0
3
C-BPF Control
340 (5-4)
7
TVO
2
7
Tilt to V-Angle offset
340 (2-0)
8
DBL
0
1
Disable Blueback Function
34C (2)
9
SSO
1
3
Speed Search Option (0-off, 1-4x,2-6x,3-8x)
34C(7-6)
10
SCH
1
7F
CH Selection for Shipping Condition NTSC models only
376 (6-0)
11
SCA
1
1
Cable/Air Selection for
NTSC models only
376 (7)
Shipping Condition
OPB
0
OP1
F1
FF
Optional Bits 1 (see below)
Option-Bits
CXP750097
4C
1
OP2
7
FF
Optional Bits 2 (see below)
4D
2
OP3
A8
FF
Optional Bits 3 (see below)
4E
3
OP4
4
FF
Optional Bits 4 (see below)
4F
NOTE
•
shaded items are fixed data.
•
Standard data listed on the Adjustment Item Table are reference values, therefore it may be different for each model and for each mode.
•
Note for Different Data
Those are the standard data values written on the microprocessor. Therefore, the data values of the modes and stored respectively in the
memory.
In case of a device replacement, adjustment by rewriting the data value is necessary for some items.