– 16 –
KV-J14P2S/J51PF2S
RM-869
SECTION 4
SELF DIAGNOSIS FUNCTION
If no acknowledgement is returned from a device which is turned "ON", the device has a problem.
In this case, one of the LED's responding to the problem device will flicker a defined number of times.
Flickering is operated by lighting the LED's for 60ss each time.
The flickering frequency responding to each failed device is shown below.
All the devices are checked one after another from the left of the table.
If an error is found, the responding LED will start flickering.
So, if more than 1 device have failed, only the one on the left side will flicker.
Device
Flickering
Frequency
NONVOLATILE
MEMORY
(IC003)
1
—
—
Y/C JUNGLE
(IC300)
3
—
—
—
—
TONE
CONTROL
(IC201)
6
Содержание TRINITRON KV-J14P2S
Страница 26: ... 26 KV J14P2S J51PF2S RM 869 MEMO ...