– 39 –
KV-ES38N90
RM-958
5-2. CONVERGENCE ADJUSTMENT
Preparation :
•
Before starting this adjustment, adjust the focus, horizontal
size and vertical size.
•
Set the Picture Mode to "STANDARD".
•
Cross hatch / Dot pattern.
(1)
Horizontal and Vertical Static Convergence
1. (Moving horizontally), adjust the H.STAT control so that the
red, green and blue dots are on top of each other at the center
of the screen.
2. (Moving vertically), adjust the V.STAT magnet so that the
red, green and blue dots are on top of each other at the center
of the screen.
3. Adjust Horizontal Trapezoid with “DAC 04 HTR” in Service
Mode to make H-Trapezoid distortion best.
4. If the H.STAT variable resistor cannot bring the red, green
and blue dots together at the center of the screen, adjust the
horizontal convergence with the H.STAT variable resistor and
the V.STAT magnet in the manner given below.
(In this case, the H.STAT variable resistor and the V.STAT
magnet influence each other, so be sure to perform
adjustments while tracking.)
1
V. STAT
2
H. STAT VR
R
R
G
G
B
B
a
a
b
b
b
R
R
G
G
B
B
a
b
3
R
R
G
G
B
B
a
a
b
b
b
Center dot
R G B
R
G
B
H. STAT VR
V. STAT
Magnet
RV702
H. STAT
Y magnet
C Board
V.STAT
Purity
BMC (Hexapole)
Содержание TRINITRON KV-ES38N90