37
END OUT Terminal
When the VCR detects the tape end or the time counter
shows “5H57M” or “7H57M” (depending on the
setting of the TAPE switch) during recording, the
output level becomes 0 V DC. To resume the 5 V
output, press the operation button (
6
EJECT,
r
REC,
)
FF,
0
REW or
z
PLAY, etc.).
Set TAPE END OUT to –3M or END on the SET UP 3
display.
• –3M: the time counter shows “5H57” (three minutes
before the tape end when using T-120 tape) or
“7H57M” (three minutes before the tape end when
using T-160 tape) and a signal is output from the
END OUT terminal (recording will be continued to
the end of the tape).
• END: the VCR detects the tape end.
Terminals
TIMER OUT Terminal
The VCR o12 V from the TIMER OUT
terminal according to the timer setting on the TIMER
SET display. The terminal outputs the signal even if
the timer recording mode is off (the TIMER button is
set to OFF).
WARNING OUT Terminal
This terminal will help you to know when something
wrong has happened to the VCR during recording.
The VCR outputs a pulse signal from WARNING
OUT terminal.
TIMER OUT terminal
Timer stops.
Timer starts.
12 V
0 V
COM terminal
WARNING OUT terminal
5 V
0 V
Tape recording stops.
Recording
mode
Output
signal
REC mode
Recording
mode
Output
signal
Rewind
Recording
0 V
5 V
Tape end
Beginning of tape
REPEAT REC mode
5 V
0 V
Rewind
Tape end
Beginning of tape
Stop
Press operation
button
COM terminal
TIMER OUT terminal
COM terminal
END OUT
terminal
To reset, press
p
STOP or
6
EJECT, if the clog detection
function works and the VCR
gives warning, otherwise, press
the reset button.
Note
To turn the clog detection function off, set CLOG
DETECT to N (no) on the SET UP 3 display.
2 sec.