background image

Printed in Japan

Sony Corporation

2003. 4 16

B&P Company

©2002

VPL-PX35 (SY)

VPL-PX40 (SY)

VPL-FX51 (SY) E

9-870-346-64

Содержание Superbright VPL-PX35

Страница 1: ...DATA PROJECTOR VPL PX35 DATA PROJECTOR VPL PX40 DATA PROJECTOR VPL FX51 PROTOCOL MANUAL 1st Edition Revised 3 ...

Страница 2: ...rt werden Um die Gefahr eines elektrischen Schlages Feuergefahr und Verletzungen zu vermeiden sind bei Wartungsarbeiten strikt die Angaben in der Anleitung zu befolgen Andere als die angegeben Wartungsarbeiten dürfen nur von Personen ausgeführt werden die eine spezielle Befähigung dazu besitzen AVERTISSEMENT Ce manual est destiné uniquement aux personnes compétentes en charge de l entretien Afin d...

Страница 3: ...etup Items 6 3 1 2 Remote Control 7 3 1 2 1 Function 7 3 1 2 2 Setup Items 7 3 2 SDAP Protocol 8 3 3 SDCP Protocol 9 3 3 1 Format 9 3 3 1 1 Header 9 3 3 1 2 Community 9 3 3 1 3 Command 10 3 3 1 4 SET Request 11 3 3 1 5 GET Request 11 3 3 1 6 ERROR Response 11 3 3 2 Items 12 3 3 2 1 Model Dependent Category 12 3 3 2 2 Equipment Information Acquisition 80 h 12 3 3 2 3 Network Information Acquisition...

Страница 4: ...2 VPL PX35 PX40 FX51 Appendix A Setup Method For VPL PX35 and PX40 A 1 Command 18 A 1 1 Setting 18 A 1 2 Display 19 A 2 Setting Command 20 Appendix B 21 ...

Страница 5: ...ded in Appendix Using an external CONTROLLER etc inputs can be switched and the power can also be turned on and off In the follow ing paragraphs CONTROLLER means an external device such as a PC which controls projector using these commands 2 RS 232C 2 1 Communication Specifications RS 232C Communication Signal Full duplex communication channels Flow control not performed Start stop synchronism sys...

Страница 6: ...CK SUM END CODE 0 x 9A DATA REPLY B5 B6 B7 Transmission from the Master side Reception in the Master side Reception in the Master side With Data B0 START CORD Common in the all FORMAT B6 CHECK SUM B1 to B5 are calculated by OR Example of Calculation 0 x A9 1010 1001 0 x A9 1010 1001 0 x A9 1010 1001 0 x 9A 1001 1010 Answer 1010 1001 Answer 1011 1011 0 x A9 0 x BB B7 END CODE Common in the all FORM...

Страница 7: ...ls SET 0 x 00 Set data GET 0 x 01 Get data SET Data to be set Refer to the Appendix B Table 2 GET Unused Set Dummy data 0 x 00 0 x 00 Check Sum End of Command Receive results of the data transmission from the Projector Start of Command Results correspond with the data transmission Refer to the Appendix B Table 3 for the data in detail 0 x 03 Express Reply data either of ACK or NAK This data does n...

Страница 8: ...mand is sent return Data may not be returned in some cases 2 4 Connection RS 232C Connection Communication is enabled by the use of a D Sub 9 Pin cross reverse cable The pin assignment of D Sub 9 Pin and D Sub 25 Pin is as follows Pins indicated as D Sub 25 Pin are not used Assured cable length 15 m However assurance may not be applicable for some cables The software for controlling the projector ...

Страница 9: ...When a communication error occurs PROJECTOR ignores the Data received until now and set into the reception standby state For undefined commands or commends determined as invalid by PROJECTOR PROJECTOR will send the NAK return Data to CONTROLLER Take note that when Data is written when the input signal of PROJECTOR is unstable that Data value will not be incorporated When INDEX specified SIRCS dire...

Страница 10: ...als Information Description Category Category of the equipment Equipment name Name of the equipment Serial number Serial number of the equipment Installation information Installation location of the equipment Community Community name of the equipment Power status Power status of the equipment m The category of projector is 0x0a The power status sets ffffh if communication error occurs Protocol The...

Страница 11: ...and picture control to be adjusted SIRCS request Enables remote control by sending the SIRCS code Status request Enables equipment status information such as power status error information and power on time to be acquired Information request Enables equipment information such as equipment name serial number and installation information to be acquired Protocol Item Description Protocol name SDCP Si...

Страница 12: ...nformation Product Name Name of equipment Maximum twelve characters In case less than twelve characters 00h is entered in the blank space Serial No Serial number is entered Power Status Power supply status of the equipment is entered Location Information of installation location Maximum twenty four characters In case less than twenty four characters 00h is entered in the blank space Header 4 Commu...

Страница 13: ...rent category number is entered the request is ignored 3 3 1 2 Community When the community Data matches the community that is set in the display equipment the request is executed Community consists of four alphanumeric characters case sensitive All display equipment has the default value SONY when shipped from the factory n Community should be entered with four characters Three characters or less...

Страница 14: ...mber of the request target Data Length This is the length of the Data accompanying the request The maximum length is 128 bytes If there is no Data it is 0 Data This is the Data accompanying the request 2 Response This section describes the format of the response command which is used to return a response to the host PC from the projector Community The same alphanumeric characters as those of the r...

Страница 15: ...scribed below Request Response 3 3 1 5 GET Request The GET request is used to acquire the value of the specified item Details of the request and the response are described below Request Response 3 3 1 6 ERROR Response When an error occurs in the contents of a request or in the result of execution NG is returned as the response OK 01h Item No n Get Data n byte 01h Item No 0 Request Item No Data Len...

Страница 16: ...g on the model Details are shown on Appendix 3 3 2 2 Equipment Information Acquisition 80 h Used to acquire the equipment information Lower byte Contents SET GET 00h Category Code O 01h Model name O 02h Serial number O 03h Installation location O O 0x8000 Category code 1 byte 0x8001 Model name Alphanumeric 12 characters If the number of characters is less than 12 the remaining digits are filled wi...

Страница 17: ...etwork setup information Lower bytes Contents SET GET 00h MAC Address O 01h IP Address O 02h Subnet Mask O 03h Default Gateway O 04h DHCP O 0x9000 Mac Address 6 bytes 0x9001 IP Address 4 bytes 0x9002 Subnet Mask 4 bytes 0x9003 Default Mask 4 bytes 0x9004 DHCP 1 byte DHCP invalid DHCP valid ...

Страница 18: ... Data 11h Not Applicable Item 80h Community Error 02 h Different Community 01h Request Error 10 h Invalid Version 01h Invalid Category 02h Invalid Request 03h Short Header 11h Short Community 12h Short Command 13h Network Error 20 h Timeout 01h Comm Error F0 h Timeout 01h Check Sum Error 10h Framing Error 20h Parity Error 30h Over Run Error 40h Other Comm Error 50h Unknown Response F0h NVRAM Error...

Страница 19: ... Data Length of the specified Item No is too long Example An attempt is made to set 25 byte Data in the installation location 0x8003 Invalid Data Data of the specified Item No is outside the setting range Example An attempt is made to set 101 in the Item when the setting range of the Item is 1 to 100 Short Data The length of Data is shorter than the value specified by the Data Length Example The a...

Страница 20: ...Invalid Category The category does not match Example 0x0B is specified in the device of Category 0x0A Invalid Request An unsupported request is specified Example Request 0x02 is specified Short Header The received Data is 1 byte Short Community The received Data is in the range of 2 to 5 bytes Short Command The received Data is in the range of 6 to 9 bytes 3 3 3 4 Network Error This is an error th...

Страница 21: ...rror A check sum error occurred in the main control microprocessor of the display Framing Error A framing error occurred Parity Error A parity error occurred Over Run Error An overrun error occurred Other Comm Error Another error occurred Unknown Response The Data cannot be processed was received 3 3 3 6 NVRAM Error Read Error Reading from NVRAM was failed Write Error Writing to NVRAM was failed ...

Страница 22: ...ddress Item Value IP address The IP address that is assigned to the network block Item Name of the setup item Value Setting value Response The following HTML is returned that enables to confirm OK or NG simply HTML TITLE IP address TITLE BODY lt Equipment name Serial number gt BR BR Result Item Value BODY HTML IP address The IP address that is assigned to the network block Equipment name Name of t...

Страница 23: ...ame of the setup item Response The following HTML is returned HTML TITLE IP address TITLE BODY lt Equipment name Serial number gt BR BR Result Item Value BODY HTML IP address The IP address that is assigned to the network block Equipment name Name of the equipment that has acquired the setup value Serial number Serial number of the equipment that has acquired the setup value Result Result OK or NG...

Страница 24: ...hanged execute restart to make the setup effective For the setup of dhcp set 1 to make DHCP effective and set 0 to make DHCP ineffective Service setup Item Description Default ad_port Port number of the Advertisement service 53862 ad_interval Broadcast interval of the Advertisement service in units of second 30 seconds ad_ip IP address of the Advertisement service 0 0 0 0 rc_port Port number of th...

Страница 25: ...ROGRESSIVE 00h 01h FILM 00h 02h ASPECT 00h 20h 16 9 00h 00h 4 3 00h 01h SCAN CONV 00h 21h OFF 00h 00h ON 00h 01h PICTURE MUTING 00h 30h OFF 00h 00h ON 00h 01h COMPUTER 00h 00h INPUT A 00h 32h COMPONENT 00h 01h VIDEO GBR 00h 02h LAMP MODE 00h 40h HIGH 00h 00h STANDARD 00h 01h GAIN RED 00h 80h Setting value 0 to 255 00h 00h to FFh GAIN GREEN 00h 81h Setting value 0 to 255 00h 00h to FFh GAIN BLUE 00...

Страница 26: ...w Save 05h W B High Save 06h Sircs 15bit category 17h Refer to table 4 _ 00h 00h Set only 3 Sircs 20bit category 19h Refer to table 5 _ 00h 00h 1 Example In case the lamp timer indicates 1000H return values are 03h upper byte and E8h lower byte 2 Example In case the software version is 1 03 return values are 01h upper byte and 03h lower byte 3 It is corresponded to single command only Table 3 Item...

Страница 27: ...ue 0 100 00h 00h to 64h Volume 00h 16h Setting value 0 100 00h 00h to 64h ColTemp 00h 17h High 00h 00h Low 00h 01h DDE 00h 18h Off 00h 00h Progressive 00h 01h Film 00h 02h Wide Mode 00h 20h Off 00h 00h On 00h 01h Scan Conv 00h 21h Off 00h 00h On 00h 01h Picture Muting 00h 30h Off 00h 00h On 00h 01h Audio Muting 00h 31h Off 00h 00h On 00h 01h Input D Signal Sel 00h 33h Computer 00h 00h Component 00...

Страница 28: ...W B Low Save 05h W B High Save 06h Sircs 15 bit category 17h Refer to table 6 _ 00h 00h Set only 4 Sircs 20 bit category 19h Refer to table 7 _ 00h 00h VPL PX35 PX40 Table 3 Item Number Data Item Data Upper byte Lower byte ACK _ 00h 00h NAK Undefined Command 01h 01h Size Error 04h Select Error 05h Range Over 06h Not Applicable 0Ah Check Sum Error F0h 10h Framing Error 20h Parity Error 30h Over Rub...

Страница 29: ...RE MUTING STATUS ON STATUS OFF CURSOR CURSOR CURSOR LENS SHIFT LENS SHIFT CURSOR FOCUS F FOCUS N ZOOM L ZOOM S CONTRAST HIGH CONTRAST _ LOW COLOR HIGH COLOR _ LOW BRITNESS BRIGHT BRITNESS _ DARK MENU VIDEO INPUT A INPUT B POWER ON POWER OFF RGB SIZE RGB SHIFT INPUT SELECT BLANKING ENTER MEMORY S VIDEO INPUT C RESET PATTERN x0 0x 1x 2x 3x 4x 5x 6x 7x x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF ...

Страница 30: ...0 FX51 2 20BIT Category VPL FX51 only Table 5 x0 0x 1x 2x 3x 4x 5x 6x 7x x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF APA DOT PHASE LENS ZOOM LENS SHIFT LENS FOCUS FREEZE LENS TOGGLE DIGITAL ZOOM KEYSTONE DIGITAL ZOOM ...

Страница 31: ...B GAIN W B BIAS SHARPNESS _ SOFT PICTURE MUTING STATUS ON STATUS OFF CURSOR CURSOR CURSOR INPUT D CURSOR CONTRAST HIGH CONTRAST _ LOW COLOR HIGH COLOR _ LOW BRITNESS BRIGHT BRITNESS _ DARK MENU VIDEO INPUT A INPUT B POWER ON POWER OFF RGB SIZE RGB SHIFT INPUT SELECT ENTER MEMORY S VIDEO INPUT C RESET x0 0x 1x 2x 3x 4x 5x 6x 7x x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF ...

Страница 32: ...X35 PX40 FX51 4 20BIT Category VPL PX35 PX40 Table 7 x0 0x 1x 2x 3x 4x 5x 6x 7x x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF APA DOT PHASE FREEZE LENS CONT TOGGLE DIGITAL ZOOM V KEYSTONE DDE TOGGLE DIGITAL ZOOM ...

Страница 33: ...riété de Sony Corporation Sony Corporation interdit formellement la copie de quelque partie que ce soit de ce manuel ou son emploi pour tout autre but que des opérations ou entretiens de l équipement à moins d une permission écrite de Sony Corporation Das in dieser Anleitung enthaltene Material besteht aus Informationen die Eigentum der Sony Corporation sind Die Sony Corporation untersagt ausdrück...

Страница 34: ...Printed in Japan Sony Corporation 2003 4 16 B P Company 2002 VPL PX35 SY VPL PX40 SY VPL FX51 SY E 9 870 346 64 ...

Отзывы: