![Sony STR-KS1000 Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/sony/str-ks1000/str-ks1000_service-manual_417235010.webp)
STR-KS1000
10
DCAC FACTORY TEST MODE
Procedure:
1. Press the buttons of standard commander (RM-AAU002) (PART
No. : 1-479-148-11 ) in order of
[TUNER]
→
[JUMP]
→
[JUMP]
→
[JUMP]
→
[MASTER VOL +]
→
[DUAL MONO]
.
2. The following content is displayed on the fluorescent indicator
tube, and DCAC factory test mode is started.
When the error happens, the following content is displayed
on the fluorescent indicator tube.
3. Connect front L-ch speaker of receiver and AUTO CAL
microphone.
4. Turn the
[MASTER VOLUME]
jog, there will be test tone sound
output from front L-ch speaker, and the following content is
displayed on the fluorescent indicator tube.
DCAC X
figure of 1 to 4
ERR SD0X
1: Abnormality of D1502 or R1100
2: Abnormality of D1501
3: Abnormality of D1500
AD - XXX
figure of 0 to 255
(depends on loudness of test tone)