![Sony STR-KG800 Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/sony/str-kg800/str-kg800_service-manual_417228013.webp)
STR-KG800
13
1. DCAC DSP Data Line Checking
After press the [TUNING MODE] button, DCAC Factory test
mode will start, below display will show:
“DCAC x”
x = 1, 2, 3, 4
If there is error happen, below display will show:
“ERR SD0x” x = 1
→
D1501 or R1530 problem
x = 2
→
D1502 problem
x = 3
→
D1503 problem
x = 4
→
D1504 problem
2. DCAC board Checking
Connect front left speaker of the receiver and AUTO CAL micro-
phone. Turn [MASTER VOLUME] jog, there will be test tone
sound output from front left speaker, and the display will change
accordingly.
“AD - xxx”
xxx = 0 to 255 (depends on loudness of test tone)
RE-BOX CLASSIFICATION TEST MODE
Procedure:
1. While pressing the [MEMORY/ENTER] and [INPUT MODE]
buttons, press the [
?/1
] button to turn on the main power.
2. The message “R.BOX
[][][]
XX” appears.
XX: times set powered on
VACS CONTROL TEST MODE
The VACS feature of the ampli
fi
er is turned off purposely.
Procedure:
1. While pressing the [MEMORY/ENTER] and [2CH] buttons,
press the [
?/1
] button to turn on the main power.
2. The message “VACS OFF” appears.