22
Chapter 2 Installation
• After turning the AIT library power off, wait at least 10 seconds before
turning it on again.
• Before transport make sure that you turn off the AIT library using the
procedure above, and that the transport screw is in the Shipping position.
Note
To avoid pressing the control buttons by accident, you can disable the control
buttons. For information on how to disable the switch, refer to “Disabling the
Buttons on the Front Panel” (page 47).
Initial Setup
Once the library has started, perform the initial setup as follows:
1
Set the date and time. (page 22)
2
Set the SCSI IDs of the AIT library and AIT drives if necessary. (page 23)
3
Set the cartridges. (page 25)
4
Configure the application programs on the host computer for use with the
unit.
Follow the instructions given in the application software manual to set up
the software for the library.
5
Connect to a network if necessary. (page 29)
Setting the Date and Time
Use the Configuration Menu of the control panel to set the date and time.
Notes
• The date and time can also be set through a browser.
• The date and time cannot be updated when the AIT library is off.
1
At the status display, press the [MENU] button for two seconds.
2
Use the
V
and
v
buttons to select “5.Configuration”, then press the
[ENTER] button.
3
Select “1.Date & Time”, then press
the [ENTER] button.
Date and Time appears.
Configuration 12:34
1.Date & Time
2.Warning
3.Barcode
Jan/01/2001 12:00:00
Japan
(GMT+ 9:00)