- SS-HQ1 Application Notes -
Ver.1.0.0 January 7, 2005
155
AWB Monitor Mode
Set ADJMODE to 31[h]
to enter AWB monitor mode.
In AWB monitor mode, the white balance gain values occurring during the AWB operation are output in
AWBOUT1-3. See “Table 11.1-6 Outputs in Monitor Mode” for the gain values which are output in each
parameter.
Note that this mode can coexist with all AWBMODE. In addition, AWB functions normally with this mode.
Table 11.1-6 Outputs in Monitor Mode
Parameter
WB gain value
AWBOUT1(CAT23_Byte1)
R gain (WBR(CAT4_Byte1))
AWBOUT2(CAT23_Byte2)
G gain (WBG(CAT4_Byte2))
AWBOUT3(CAT23_Byte3)
B gain (WBB (CAT4_Byte3))
AWBOUT4(CAT23_Byte4) 0
Fixed
AWB Co-process Mode
Set ADJMODE to 32[h] to enter AWB co-process mode.
In AWB co-process mode, the OPD evaluation values for AWB controls are output in AWBOUT1-4. See “Table
11.1-7 Outputs in Co-process Mode” for the individual output values.
Table 11.1-7 Outputs in Co-process Mode
Parameter
Output value
AWBOUT1(CAT23_Byte1) (R-B)/G
(lower)
AWBOUT2(CAT23_Byte2) (R-B)/G
(upper)
AWBOUT3(CAT23_Byte3) (R+B-2G)/G
(lower)
AWBOUT4(CAT23_Byte4) (R+B-2G)/G
(upper)
Note
AWB controls other than OPD integration are stopped in this mode, regardless of the AWB mode.