36
Error Messages
C
h
a
p
te
r 4
O
th
e
rs
Error Messages
The error messages are displayed in the STATUS MESSAGE window on the left side of projector and the Error display
window of the SRX Controller. If there are two or more messages, a displayed message changes each five seconds.
No.
Error messages
Meaning
Remedy
1
INPUT-A POWER ALERT
Trouble with power of INPUT A board
Replace the INPUT A board.
2
INPUT-B POWER ALERT
Trouble with power of INPUT B board
Replace the INPUT B board.
3
INPUT-C POWER ALERT
Trouble with power of INPUT C board
Replace the INPUT C board.
4
INPUT-D POWER ALERT
Trouble with power of INPUT D board
Replace the INPUT D board.
5
PR-284_1 POWER ALERT
Trouble with power of PR-284 board at
the top
Replace the corresponding PR-284 board.
6
PR-284_2 POWER ALERT
Trouble with power of PR-284 board on
the second row
Replace the corresponding PR-284 board.
7
PR-284_3 POWER ALERT
Trouble with power of PR-284 board on
the third row
Replace the corresponding PR-284 board.
8
PR-284_4 POWER ALERT
Trouble with power of PR-284 board on
the fourth row
Replace the corresponding PR-284 board.
9
24V POWER SUPPLY ALERT
The projector has failed to supply 24V
power.
Overload on the 24 V line. Replace the AC inlet
on the projector.
10
16V POWER SUPPLY ALERT
The projector has failed to supply 16V
power.
Overload on the 16 V line. Replace the AC inlet
on the projector.
11
PR-284_1 DETACHED
The PR-284 board is not attached
correctly on the top row.
Attach the PR-284 board on the top row correctly.
12
SXRD PANEL TEMPERATURE
ALERT
The temperature of the panels is too
high.
Check the panel cooling fan or the ventilation
holes for intake.
13
LAMP_A FAN ALERT
Trouble with the sirocco fan for Lamp A,
or the harness is disconnected or down.
Check the connection of the Lamp A fan, or
replace the fan.
14
LAMP_B FAN ALERT
Trouble with the sirocco fan for Lamp B,
or the harness is disconnected or down.
Check the connection of the Lamp B fan, or
replace the fan.
15
LAMP_A POWER SUPPLY UNIT
FAN ALERT
Trouble with the fan for Lamp A power
(ballast), or the harness is disconnected
or down.
Check the connection between the Lamp A power
and the SY board, or replace the fan for Lamp A
power.
16
LAMP_B POWER SUPPLY UNIT
FAN ALERT
Trouble with the fan for Lamp B power
(ballast), or the harness is disconnected
or down.
Check the connection between the Lamp B power
and the SY board, or replace the fan for Lamp B
power.
17
PR-284 FAN FAILURE
Trouble with the fan for PR-284 board,
or the harness is disconnected or down.
Check the connection between the fan located on
the side of the board shield and the SY board, or
replace the fan.
18
OPTICAL UNIT TEMPERATURE
ALERT
The temperature of the optical unit is too
high, or the harness is disconnected or
down.
The ventilation hole for intake on the projector
may be blocked. Check the projector is installed
properly.
19
LAMP_A TEMPERATURE
ALERT
The temperature of Lamp A is too high,
or the harness is disconnected or down.
The ventilation hole for intake on the projector
may be blocked. Check the projector is installed
properly.
20
LAMP_B TEMPERATURE
ALERT
The temperature of Lamp B is too high,
or the harness is disconnected or down.
The ventilation hole for intake on the projector
may be blocked. Check the projector is installed
properly.
21
LAMP_A HOUSE DETACHED
The projection lamp house of Lamp A is
detached, or the harness is disconnected
or down.
Check the attachment screw on the projection
lamp house of Lamp A or the harness.
Содержание SRX-T105