Enter the data associated with each address by referring to the
“EEPROM data” in the following table.
Writing procedure:
1. Input the address number (3 digit) of EEPROM.
2. Press the
[#]
key to enter the address number and display read
data (8 digit=4 byte).
3. If rewrite the data, input the rewriting data (8 digit=4 byte).
4. Press the
[#]
key to enter the rewriting data.
5. To release this mode, press the
[VOL --]
key.
EEPROM data:
Address
Data (hexadecimal)
(hexadecimal)
1st byte
2nd byte
3rd byte
4th byte
754
(ID1)
(ID2)
F6
(C-sum)
714
81
01
00
(C-sum)
718
03
05
0C
(C-sum)
71C
C2
C0
00
(C-sum)
720
A9
3D
1C
(C-sum)
724
48
C7
04
(C-sum)
728
50
03
51
08
72C
52
08
54
0D
730
5A
06
5D
02
734
60
0B
66
0F
738
70
07
FF
83
73C
FF
FF
FF
(C-sum)
740
FF
FF
FF
(C-sum)
744
FF
FF
FF
(C-sum)
690
90
E8
2A
(C-sum)
694
6A
AA
01
(C-sum)
794
01
00
00
(C-sum)
Contents of EEPROM data:
Address
Data (hexadecimal)
(hexadecimal)
1st byte
2nd byte
3rd byte
4th byte
754
ID1
ID2
RF parameter
C-sum
714
reserved
C-sum
718
audio parameter
RF parameter
C-sum
71C
reserved
C-sum
720
RF parameter
C-sum
724
audio parameter
C-sum
728
72C
730
RF parameter
734
738
73C
C-sum
740
reserved
C-sum
744
C-sum
690
audio parameter
C-sum
694
C-sum
794
H-No.
reserved
C-sum
Note:
ID1, ID2 : ID numbers in hexadecimal notation (refer to “6. TEST MODE
B”)
C-sum
: Check sum value (After entering the data up to 3 bytes, press
the
[PROGRAM]
key to start automatic calculation.)
H-No.
: Number of registered handset
5. TEST MODE F (DSP Control Mode)
In the test mode idling status, press the
[6]
key to active this mode
and display “TEST F”.
CPT detection
When detect stutter tone, it lights up the
[IN USE]
LED.
6. TEST MODE B (Writing the ID number)
Note:
Though the “TEST MODE E” handles the ID numbers as hexa-
decimal numbers, the “TEST MODE B” handles them as decimal
numbers. Both are different in numerical notation format only, and
net values are same.
The ID numbers written on the bottom of base unit are decimal
numbers, and accordingly use the “TEST MODE B” when enter-
ing the ID numbers.
In the test mode idling status, press the
[7]
key to active this mode
and display as below.
*
: Already registered ID number
[]
: Inputted ID number (initial values are all blank)
IF a wrong ID number was entered by mistake, press the
[VOL--]
key to return to the test mode idling status, then re-enter correct
ID number.
7. INITIALIZE THE EEPROM
In the test mode idling status, EEPROM (IC303) and Flash memory
(IC403) are all cleared except VP setting value when the
[ERASE]
key is pressed.
When execute this operation, it erases stored data (phone dictio-
nary, caller ID, message data).
TEST B 224******
ID=224
[][][][][][]
display example
Содержание SPP-S2720
Страница 51: ...51 SPP S2720 MEMO ...