53
Additional Information
SLV-X837AS 3-858-900-11 (1)
Troubleshooting
Symptom
The ON/STANDBY switch
does not function.
The power is turned on but the
VCR does not operate.
The clock has stopped and
“–:– –” lights in the display
window.
The playback picture does not
appear on the TV screen.
The picture is not clear.
Additional Information
If you have any questions or problems not covered below, please consult your
nearest Sony service facility.
Power
Clock
Playback
Symptoms caused by contaminated video heads
continued
Remedy
• Connect the mains lead to mains securely.
• Moisture condensation occurs. Turn the power off,
unplug the mains lead, and leave the VCR to dry for
over one hour.
• The clock stops if the VCR is disconnected from the
mains for more than an hour. Reset the clock (and
timer).
• Make sure the TV is set to the video channel. If you
are using a monitor, set it to video input.
• Adjust the tracking with the TR/– buttons.
• Make sure the colour system is correctly set to the
system that the tape was recorded in.
• The video heads are dirty (see below). Clean the video
heads using the Sony V-25CL video head cleaning
cassette. If this cleaning cassette is not available in
your area, have the heads cleaned at your nearest Sony
service facility (a standard service charge will be
required). Do not use a commercially available wet-
type cleaning cassette, as it may damage the video
heads.
• The video heads may have to be replaced. Consult
your local Sony service facility for more information.
• Normal picture
• Rough picture
• No picture (or
black & white
screen appears)
• Unclear picture
initial