13
Terminator Power Control DIP switch
This DIP switch determines whether terminator power is supplied to the
SCSI bus. To enable terminator power, set position 5 [Terminator Power]
switch to ON.
Cleaning Request Mode
Periodic cleaning requests can be enabled by a DIP switch.
ON
OFF
1
2
3
4
5
6
7
8
When switch 6 is ON, cleaning requests are enabled. When enabled, the
“CLEANING REQUEST” LED on the front panel lights after every 100
hours of operation.
When this LED lights, clean the drive with a head cleaning cartridge.
Note
To maintain the drive in optimum condition in environments affected by dust and other
contaminants, we recommend keeping cleaning requests enabled.
1
Drive Mode
2
Drive Mode
3
Drive Mode
4
Drive Mode
5
Terminatore Power
6
Periodic Cleaning Req (ON)
7
DC Control (1)
8
DC Control (2)