4-17
SAL24105 (3.5-4.5/24-105) (24-105mm F3.5-4.5)
2. Adjustment Procedure
1)
Adjust the diameter of inscribed circle of iris blades to about 16.6 mm by rotating the aperture blade holding ring. (Fig. 4-2-9.)
2)
Operate the preset ring and check the shape of inscribed circle of iris blades again.
3)
Check the tolerance of iris again and repeat the adjustment/check until the tolerance of iris meets the specification.
4)
After completing the adjustment, apply the adhesive bond (B-10) to three indicated portions.
Fig.4-2-9
16.5mm
Apply the adhesive bond (B-10)
Aperture Blade Holding Ring
Preset Lever
Preset Ring